10
87D0058
SB50HB Series Woodburning Fireplace
3 ft. Min.
FP1883
multistory install
8/08
INSTaLLaTION preparaTION
&0
CHIMNEYLOCATION
Figure 8
Preferred Location
Poor
Location
FP188
18’ Min.
FP1881
single story install
8/08
Chimney Cap
Single Story Installation with attic Space
Storm Collar
Flashing
Flue Outlet Height
3’ Min. or ’ Above
any Point within 10’
See Table
1 for Roof
Opening Size
Attic Space
Firestop Spacer
(” Air space
Clearance to
Combustibles)
Chimney
Sections
17”
Square
Opening
in Joist
FP1881
Figure 7
” Minimum Clear-
ance to Combus-
tibles
Multiple Story Installation
Chimney Cap
Storm Collar
(Included with cap)
Flashing
See Table 1 for
Roof Opening
Size
Attic Space
Firestop
Spacer (”
Air Space
Clearance to
Combustibles)
” Clearance to
Combustibles (Min.)
17” Square
Opening in
Joist
Max.
Installation
Height -
86 ft.
Third Floor
Area
Second
Floor Area
First Floor
Area
Flue Outlet Height
17” Square
Opening in
Joist
17” Square
Opening in Joist
Firestop
Spacer
Firestop
Spacer
FP1883
Figure 9
INSuLaTINg FIrepLaCe eNCLOSure FOr
COLd CLIMaTeS
If you live in a cold climate, it is not required but highly
recommended
that you insulate the fireplace enclosure to
eliminate cold air penetration as much as possible.
Insulate base of fireplace with a noncombustible insulation
rated for a minimum of 300° F. Insulating is very important for
outside wall installations over a concrete slab. If fireplace is
installed on a platform, insulation should be placed on top of
the platform before fireplace is set.
Figure 6
When a fireplace is installed in a chase or on an outside wall,
enclosure should be treated like any outside wall in a home.
Insulation should be installed on the inside wall as well as the
outside wall(s). In a chase, it is also a good idea to install a
firestop at the first ceiling level above the fireplace and enclose
the chase with sheeting material. Insulation may then be in-
stalled above sheeting material to assure the space around
the fireplace is totally protected.
Figure 6
CauTION: WHeN INSTaLLINg a FIrepLaCe IN aN IN-
SuLaTed eNCLOSure, Be Sure aLL requIred aIr
SpaCeS are MaINTaINed.
Figures 7 & 9