8
87D0058
SB50HB Series Woodburning Fireplace
TrIM and dOOr INSTaLLaTION
Installation of Noncombustible Trim Materials to the Front Face of the Fireplace
M2233
combustible surround
Figure 32
Combustible Surround placement
Combustible Surround Materi-
als may be placed inside the
shaded areas. Combustibles
may not overlap edge of black
painted face more than 1/8”.
Do Not Restrict
Side Air Inlets
Extend line from op-
posite rear corner of
firebox past inside open-
ing of the front face side
panel.
Outline of
Fireplace
Firebrick
gLaSS dOOr INSTaLLaTION
This fireplace has been tested and listed for use with op-
tional Models WSB60B and GD60B glass doors.
Refer to the instructions provided with the doors for prop-
er installation.
12”
Max.
M1002
Mantel install
8/08
Mantel Installation
Combustible Framing
Members to Top of Spacers
Combustible Mantel
Top Edge of Fireplace
18” Min. From Fireplace Opening to
Bottom of Combustible Mantel
(Manufacturer Recommendation)
Top Edge of Fireplace
Opening
NOTe:
If Model WSB60 glass doors are to
be used, noncombustible trim attached to the
face of the fireplace must not extend over the
screen cover at the top of the firebox opening.
The screen cover will have to be removed be-
fore model WSB60 glass doors can be installed.
Noncombustible trim must not extend over each
side of the fireplace into the firebox opening to
avoid interference with installation of the model
WSB60 glass doors.
M100
FP33
-
FACINGINSTALLATION
Noncombustible Facing
Material
Combustible Framing Members
Facing Material to Top of
Spacers
Figure 31
CauTION:
Do not allow any trim materials to extend closer than 3/8 inch to the vertical edges of the
firebox opening if glass doors are to be installed.
Use Only Noncombustible Materials
Below Top of Spacers
Fireplace Face
Steel Lintel
(Optional)
CauTION:
Do not cover or
restrict vent areas with any trim
materials.
WarNINg:
The space between the face
of the fireplace and the noncombustible
facing material must be sealed. Failure
to properly seal this crack can cause
a possible fire hazard and will void the
Vermont Castings Group warranty.
M101
WARNING
!
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.