49
20306759
Radiance
®
Direct Vent Gas Heater
FUEL CONVERSION
All Models
Replace burner making sure venturi on bottom of ember
bed aligns with orifice and is seated properly on air shutter
assembly. Make sure burner is slid into place at a slight
angle and opposite to how it was removed. When burner is
slid into place, the three (3) pem studs should slide down
through clearance holes into the bottom of the control
panel.
Thread and tighten 3/8” nuts back onto pem studs on
underneath side of control panel, reversing Step 1 shown
in Figure 82.
Refer to Log Installation section of this manual to reinstall
logs.
Place conversion label supplied with kit on rating plate.
Replace glass and stove front.
Restore gas to system and relight appliance according to
Lighting Instructions on Page 32 (RADVT models) or Page
35 (RADVTSC models).
Leak check the system using a gas leak detector solution.
Relight the main burner in both the “HI” and “LO” positions
to verify proper burner ignition and operation.
Conversion is complete.
RADVTSC Series Models
• Using Torx T20 driver or slotted screwdriver, remove
and discard the regulator and rubber gasket in the face
of the valve. Figure 85
• Install the new regulator with rubber gasket from the
conversion kit. Make sure the gasket is seated properly.
Figure 85
•
Convert the control box by using a small flat head
screwdriver. Lift the conversion cap from the control box
and replace with new one marked LP. Be sure to place
correctly. Figure 86
KT1196
SC valve regulator
KT1193
conversion cap
Regulator
Rubber gasket
Fig. 85
Valve Regulator
Fig. 86
Convert Control Box