Radiance
®
Direct Vent Gas Heater
INSTALL ON/OFF SWITCH - RADVT MODELS
The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove
shroud (when facing shroud) using two screws and
existing holes in shroud. (Figure 46)
2. Run wires down back of stove, under bottom of rear
shroud to valve.
3. Attach wires to valve terminals. (Figure 47)
ST315
attach switch assy
1/31/00 djt
Switch As-
sembly
Screws
Existing
Holes
ST315
Fig. 46 Attach switch assembly to rear shroud.
THERMOSTAT OR WALL SWITCH
CONNECTION (OPTIONAL)
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge thermostat
wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
Maximum Run
18
20 feet
16
20 - 40 feet
14
up to 60 feet
1. Install the wall thermostat or switch in the desired
location and run the wires to the stove location. Ter-
minate these leads with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Figure
47)
FP1622
Fig. 47 Install wiring to switch before connecting to valve.
P
ILO
T
TPTH
TP
TH
FP1622
SIT valve w/switch
SIT VALVE
Valve
Thermopile
ON/OFF Switch or
Millivolt Thermostat
FP1909a
signature command valve
alternate view
8/08
Pressure Inlet
Pressure Outlet
Pilot Adjust-
ment Screw
FP1909a
Fig. 48 Signature Command Valve
SIGNATURE COMMAND
®
SYSTEM
General
RADVTSC models are equipped with the Signature Com-
mand control valve (Figure 48) which operates on 6 volts.
The A/C module plugs into the stove junction box A/C power
supply. Four (4) “AA” batteries are used for back up during
power outages.
The Signature Command System can also be operated
without A/C power. The system can run on four (4) “AA” bat-
teries for approximately six (6) months under normal use.
A/C power must be used to power the A/C module and
blowers.
ASSEMBLY AND INSTALLATION
WARNING
Electrical connections should only be performed by a
qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest edition)
and Canadian Electrical Code, CSA C22.1.
CAUTION
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and dan-
gerous operation.