20306748
5
MLDV Series Gas Fireplace
PRODUCT FEATURES
•
This appliance has been certi
fi
ed for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home appr-oved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
PRODUCT SPECIFICATIONS
Figure 1 -
MLDV Series Fireplace (Millivolt Control shown)
Off/Pilot/On Knob
Hi/Lo Knob
On/Off/RS
Switch
Ignitor
5/8" Nailing
Flange
1/2" Nailing
Flange
Insulation Board
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are cer-
ti
fi
ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installation at eleva-
tions above 4,500 feet (1,370 m).
GAS PRESSURES
Natural Propane
(LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Max.Input Min.
Input Ori
fi
ce
Model
Fuel
BTU/h
BTU/h
Size
MLDV500NV
Nat.
34,000
22,000
#33
MLDV500PV
LP
34,000
27,000
1.8 mm
MLDV500NSC Nat.
34,000
22,000
#33
MLDV500PSC LP
34,000
27,000
1.8 mm
GAS SPECIFICATIONS & ORIFICE SIZE