background image

User Guide quadroPOL

4

Control Elements

quadroPOL offers four identical channels, each with two inputs, one control and one output.

INPUT

A signal applied to this input can be modified by 

LEVEL

 

w

 and a control voltage, being applied to 

CV 

IN

 

r

.

LEVEL

LEVEL

 

w

 adjusts the level for the signal applied to 

INPUT

 

q

. It works bipolar, meaning, that in its center 

position, the applied input signal is suppressed and 
the channel is closed. Turning this control to the right 
will increase the level. The level also increases when 
turning this control to the left, but in this case with 
reversed polarity. This function is called polarizer.

LEVEL

 

w

 has a dead-zone around its center position to 

make it easier finding and hitting zero.

In most cases there will be no audible differences 
between positive and negative amplitudes when using 
complex audio signals. When using sub-audio signals, 
i.e. LFO waveforms, the difference will be audible 
immediately at its modulation destination:

Figure 2: quadroPOL front

Summary of Contents for quadroPOL

Page 1: ...Bedienungsanleitung User Guide quadroPOL...

Page 2: ...its simple layout quadroPOL can effect a lot of things and full multiple purposes Mixer Polarizer Attenuator Ring Modulator VCA CV Source Inverter Because of this the application section in this manua...

Page 3: ...the quadroPOL module one ribbon cable 10 pole to 16 pole four M type screws 3 x 6 mm with matching plastic washers this operating manual Setup quadroPOL was designed to be mounted and used in Eurorac...

Page 4: ...ribbon cable s 16 pole connector to an empty plug socket of your frame s system bus Make sure the color coded side of the cable points towards 12 volts Connecting the ribbon cable with reverse polari...

Page 5: ...ressed and the channel is closed Turning this control to the right will increase the level The level also increases when turning this control to the left but in this case with reversed polarity This f...

Page 6: ...OUTPUT e connector Turning the control counterclockwise provides a negative control voltage of up to 5 volts OUTPUT Here you ll get the signal out of quadroPOL s channel A jumper on the module s circ...

Page 7: ...utput of one channel will be forwarded and summed up with the following channel factory setting for all channels With this feature activated quadroPOL can for example be used as mixer see Mixer on pag...

Page 8: ...between zero center setting for LEVEL w and 100 fully right quadroPOL can be used to attenuate control voltages as well as audio signals It s an essential function in modular systems Inverter A signal...

Page 9: ...roPOL that rotates between normal in phase and inverted out of phase states To avoid this you may either need to use a LFO that only provides a positive amplitude output or you need to apply a suffici...

Page 10: ...r audio source at the channels INPUTs q Ring Modulator In case two continuous signals with consistently changing positive and negative amplitudes waveforms are fed into inputs CV IN r and INPUT q ring...

Page 11: ...s a range of 5 volts left to 5 volts right The control voltage can be used for multiple purposes In case the tuning of a VCO or any other CV controllable parameter needs to be adjusted more detailed a...

Page 12: ...cations Levels optimum input level INPUT 5 V optimum input level CV IN 5 V generated DC 5 V 5 V Power Consumption 12 V 45 mA 12 V 35 mA 5 V Dimensions and Weight Width Height 10 HP 129 00 mm 3 U Depth...

Page 13: ...HDB electronic GmbH Badesteig 20 08258 Markneukirchen GERMANY Phone 49 0 37422 4027 0 Email info vermona com Web www vermona com...