![VERITAS NetBackup 5230 Hardware Installation Manual Download Page 126](http://html.mh-extra.com/html/veritas/netbackup-5230/netbackup-5230_hardware-installation-manual_1004769126.webp)
5
Locate the SAS port LEDs.
Note:
The illustration shows the LEDs for port B in the top I/O module. The
LEDs for all six ports are the same.
The Fault LED is the LED that is farthest from the SAS port.
The Activity LED is the LED that is closest to the SAS port.
The following table describes the SAS port LEDs.
Note that the combination of both LEDs provides the status.
Fault (amber) LED
Activity (green) LED
Status
Off
Off
No cable present
Off
On
Cable present, no activity
Off
Blinking if one or more disk
drives are active.
Cable present, all links
active
On
Off
Critical fault
Blinking at a rate of one
second on, and one second
off.
Blinking if one or more disk
drives are active.
Non-critical fault
6
Move to the front of the storage shelf.
126
Adding 2U12 storage shelves to an operational NetBackup 5230 Appliance
Turning on the hardware and verifying operation