To install storage shelf rails
1
Identify the front and the rear of each rail. The following illustration shows the
front of the left-hand and the right-hand rails. Red arrows show the pins that
fit into the rack.
2
Align the rails with the rack holes. Be sure to use the same holes on each side
of the rack.
3
Place the left rail inside the rack. Extend the front and back of the rail to fit into
the rack.
4
Secure the front pins (1) and the rear pins (3).
5
Insert the screw (2) in the front of the rail. Do not over-tighten the screws.
6
Repeat for the right rail.
100
Adding 2U12 storage shelves to an operational NetBackup 5230 Appliance
Installing 2U12 storage shelves into the rack