Table 1-5
System Status LED states
(continued)
Description
Criticality
State
Color
System degraded: (continued)
■
In mirrored configuration, when memory
mirroring takes place and system loses
memory redundancy.
■
Battery failure
■
BMC executing in uBoot. (Indicated by
Chassis ID blinking at 3Hz). System in
degraded state (no manageability). BMC
uBoot is running but has not transferred
control to the BMC Linux. Server will be in
this state 6-8 seconds after BMC reset while
it pulls the Linux image into flash.
■
BMC booting Linux. (Indicated by Chassis ID
solid ON). System in degraded state (no
manageability). Control has been passed
from BMC uBoot to BMC Linux itself. It will
be in this state for 10-20 seconds.
■
BMC Watchdog has reset the BMC.
■
Power unit sensor offset for configuration
error is asserted.
■
Hard disk drive HSC is offline or degraded.
Degraded
The system is
operating in a
degraded state
although still
functional.
or
The system is
operating in a
redundant state
but with an
impending failure
warning.
~1-Hz blinking
Green
Non-fatal, although the system is likely to fail due
to the following issues:
■
Critical threshold crossed – Voltage,
temperature (including HSBP temp), input
power to power supply, output current for
main power rail from power supply and
PROCHOT (Therm Ctrl) sensors.
■
VRD Hot asserted
■
Minimum number of fans to cool the system
not present or failed
■
Hard drive fault
■
Power Unit Redundancy sensor – Insufficient
resources offset (indicates not enough power
supplies present)
■
Correctable memory error threshold has been
reached when the system is operating in a
non-sparing and non-mirroring mode.
Non-critical
The system is
operating in a
degraded state
with an
impending failure
warning.
However, the
system is still
functioning.
~1-Hz blinking
Amber
14
About the Veritas 5150 Appliance
Appliance control panel