background image

Veritas 5150 Appliance Product Description Guide

Last updated: 2019-12-02

Legal Notice

Copyright © 2019 Veritas Technologies LLC. All rights reserved.

Veritas, the Veritas Logo, and NetBackup are trademarks or registered trademarks of Veritas
Technologies LLC or its affiliates in the U.S. and other countries. Other names may be
trademarks of their respective owners.

This product may contain third-party software for which Veritas is required to provide attribution
to the third party (“Third-party Programs”). Some of the Third-party Programs are available
under open source or free software licenses. The License Agreement accompanying the
Software does not alter any rights or obligations you may have under those open source or
free software licenses. Refer to the Third-party Legal Notices document accompanying this
Veritas product or available at:

https://www.veritas.com/about/legal/license-agreements

The product described in this document is distributed under licenses restricting its use, copying,
distribution, and decompilation/reverse engineering. No part of this document may be
reproduced in any form by any means without prior written authorization of Veritas Technologies
LLC and its licensors, if any.

THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED
CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR
NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH
DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. VERITAS TECHNOLOGIES LLC
SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS
DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS
SUBJECT TO CHANGE WITHOUT NOTICE.

The Licensed Software and Documentation are deemed to be commercial computer software
as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19
"Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq.
"Commercial Computer Software and Commercial Computer Software Documentation," as
applicable, and any successor regulations, whether delivered by Veritas as on premises or
hosted services. Any use, modification, reproduction release, performance, display or disclosure
of the Licensed Software and Documentation by the U.S. Government shall be solely in
accordance with the terms of this Agreement.

Veritas Technologies LLC
2625 Augustine Drive
Santa Clara, CA 95054

http://www.veritas.com

Summary of Contents for 5150

Page 1: ...Veritas 5150 Appliance Product Description Guide ...

Page 2: ...thorization of Veritas Technologies LLC and its licensors if any THE DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID VERITAS TECHNOLOGIES LLC SHALL NOT BE ...

Page 3: ...ation is available on the Veritas website https www veritas com content support en_US dpp Appliances html Documentation feedback Your feedback is important to us Suggest improvements or report errors or omissions to the documentation Include the document title document version chapter title and section title of the text on which you are reporting Send feedback to APPL docs veritas com You can also...

Page 4: ...Intel X540 T2 dual port 10Gb Ethernet card 18 Intel I350 T4 Quad port 1Gb Ethernet card 19 Mellanox ConnectX 4 Lx EN MCX4121A ACAT Ethernet card 21 SAS tape out adapter 22 Chapter 2 Veritas 5150 Appliance cables 23 Power cables 23 AC power cable with the IEC 60320 C14 plug 24 AC power cable with the NEMA 5 15p plug 24 Network cable 25 Multi mode fiber optic cable 25 Twinaxial copper cables 26 Appe...

Page 5: ...ompliance Class A Compliance 33 Product ecology compliance 33 Electromagnetic compatibility notices 34 FCC Verification Statement USA 34 ICES 003 Canada 35 CE Declaration of Conformity Europe 35 VCCI Japan 35 BSMI Taiwan 35 Index 36 5 Contents ...

Page 6: ...liance disk drives Appliance control panel Appliance rear panel Appliance front panel USB port Appliance I O configuration options About the appliance The Veritas 5150 Appliance is a hardware and software storage system that can scale to 14 TB of usable capacity Figure 1 1 Veritas 5150 Appliance The Veritas 5150 Appliance supports the following software Flex version 1 3 and later 1 Chapter ...

Page 7: ...Available internal storage capacities of 14TBs The available capacity can be allocated either in part or in whole to a deduplication pool or to an AdvancedDisk pool non deduplicated storage Performance and capacity The deduplication engine provides up to 100 times reduction in storage The client side plug in provides similar levels of bandwidth reduction The type of data can impact the amount of s...

Page 8: ...is shipped These drives should not be moved into different slots or otherwise rearranged RAID levels See Appliance rear panel on page 17 Rear panel ports Locating the appliance serial number The serial number is located on the rear panel of the appliance and begins with the letters VTAS You can also find the serial number in the pull out tab on the front of the appliance You have to remove the fro...

Page 9: ... Slot Boot OS Intel 2280 M 2 SATA SSD 480GB RAID 1 0 1 Internal storage SEAGATE 8TB SAS 12G 7 2K RPM 3 5 RAID 10 4 5 6 7 Certificate SMART 2280 M 2 SATA SSD 32GB N A N A Appliance control panel The front panel of the Veritas 5150 Appliance includes a small panel that is attached to the right side of the device The panel provides basic control of the system as well as LED status indicators such as ...

Page 10: ...ID LED and the blue server board LED on and off The system ID LED identifies the system for maintenance when it is racked with similar server systems System ID button with integrated LED The front control panel includes one LED for each of the 1 GB RJ45 port on the Quad Gigabit Ethernet OCP module When network links are detected on the controllers the LEDs are activated and remain solid green The ...

Page 11: ...ent health of the appliance Two locations are provided for you to monitor the health of the system You can find the first location on the front control panel while the second location is located on the back edge of the server board It is viewable from the rear of the appliance Both LEDs show the same state of health See About the System Status LED states on page 12 System Status LED The appliance ...

Page 12: ...feature The first location is on the Front Control Panel while the second location is on the back edge of the server board Table 1 5 System Status LED states Description Criticality State Color System power is off AC and or DC System is in EuP Lot6 Off Mode System is in S5 Soft Off State Not ready Off The system is not operating No color Indicates that the system is running in S0 State and its sta...

Page 13: ...power supply and Processor Thermal Control Therm Ctrl sensors Power supply predictive failure occurred while redundant power supply configuration was present Unable to use all of the installed memory more than one DIMM is installed Correctable errors over a threshold and migrating to a spare DIMM memory sparing This indicates that the system has no spared DIMMs a redundancy lost condition The corr...

Page 14: ...SC is offline or degraded Degraded The system is operating in a degraded state although still functional or The system is operating in a redundant state but with an impending failure warning 1 Hz blinking Green Non fatal although the system is likely to fail due to the following issues Critical threshold crossed Voltage temperature including HSBP temp input power to power supply output current for...

Page 15: ...s condition Both uBoot BMC FW images are bad Chassis ID shows blue solid on for this condition 240 VA fault Fatal error in processor initialization Processor family not identical Processor model not identical Processor core thread counts not identical Processor cache size not identical Unable to synchronize processor frequency Unable to synchronize QPI link frequency Uncorrectable memory error in ...

Page 16: ...ates The power supply module has a bi color LED to represent the current status of the power supply The following table provides a description of each power supply state Table 1 8 Power supply LED states Power supply condition LED Output on and ok Solid green No AC power to all power supplies Off AC is present but only 12 VSB or is in cold redundant state 1 Hz blinking green AC cord is unplugged o...

Page 17: ...ply The following table provides a description of the SSD LED states Table 1 9 SSD LED states Power supply condition LED SSD is receiving power Solid green No power to the SSD Off Drive activities to the SSD are on going Blinking green Appliance rear panel The rear panel of the appliance contains several default ports that are embedded Figure 1 4 Rear panel The following list describes the numbere...

Page 18: ...er Appliance front panel USB port The Veritas 5150 Appliance front panel includes two USB 3 0 compliant port that supports a data transfer rate of up to 5 Gb second Figure 1 5 Veritas 5150 Appliance front USB port Appliance I O configuration options The Veritas 5150 Appliance has one functional PCIe slot with three PCIe card options 2 x 10 GbT 2 x 10 25 GbE 4 x 1 GbT Intel X540 T2 dual port 10Gb E...

Page 19: ...ge humidity PCIe v2 1 System interface type 5 0 GT s gigatransfers per second 8 Lane Speed and slot width 100 Mbps 1 Gbps 10 Gbps Data rate supported per port LINK solid and ACTIVITY blinking LINK SPEED green 10Gbps yellow 1Gbps LED indicators 200 LFM linear feet per minute Air Flow minimum Intel I350 T4 Quad port 1Gb Ethernet card The Intel I350 T4 adds 4 extra 1Gb RJ45 connections to the Veritas...

Page 20: ... 32 F to 131 F Operating temperature 40 C to 70 C 40 F to 158 F Storage temperature 90 non condensing relative at 35 C Storage humidity PCIe v2 1 System interface type 5 0 GT s gigatransfers per second 4 Lane Speed and slot width 1GBase T Cat 5e or higher 100Base T Cat 5 or higher 10Base T Cat 3 or higher Cabling Distances 20 About the Veritas 5150 Appliance Appliance I O configuration options ...

Page 21: ...X 4 Lx EN MCX4121A ACAT Ethernet card The Mellanox ConnectX 4 Lx EN Ethernet card supports both optical FCoE and copper twinax traffic at 10Gbps Ethernet line rate speeds Table 1 12 Mellanox ConnectX 4 Lx EN MCX4121A ACAT Ethernet card specifications Specification Item Full Height Bracket height Typical 9 6 watts Maximum 15 0 watts Power consumption 0 C to 55 C 32 F to 131 F Operating temperature ...

Page 22: ...minute Air Flow minimum SAS tape out adapter The SAS tape out adapter is used to connect external SAS devices to the Veritas 5150 Appliance The adapter comes standard on all configurations of Veritas 5150 Appliance The SAS tape out adapter assembly includes a port for external SAS 3 device connections and an attached internal SAS 3 cable The adapter s internal SAS 3 cable connects to Connector 0 o...

Page 23: ... supply on the appliance The other end of the cable is connected to an external Power Distribution Unit PDU on the rack Power cables include a live line a neutral line and a grounding line Note If your power distribution unit is not compatible with the IEC 60320 C14 plug or the NEMA 5 15p plug then Veritas recommends that you purchase your power cable locally Make sure that the power cable meets o...

Page 24: ... supply Power Distribution Unit PDU on a rack A AC power connector IEC 60320 C13 to the appliance B Cable rating 15A 250V AC power cable with the NEMA 5 15p plug Figure 2 2 NEMA 5 15p plug AC power connector NEMA 5 15p to an external power supply Power Distribution Unit PDU on a rack A 24 Veritas 5150 Appliance cables Power cables ...

Page 25: ...nds of the cable are RJ45 connectors Figure 2 3 Network cable See Power cables on page 23 See Multi mode fiber optic cable on page 25 See Twinaxial copper cables on page 26 Multi mode fiber optic cable The Veritas 5150 Appliance communicates with the Fibre Channel switch through a multi mode fiber optic cable One end of the multi mode fiber optic cable connects to the 10GbE service network port Th...

Page 26: ... 2 Supported SFPs are listed Finisar JDSU See Power cables on page 23 See Network cable on page 25 See Twinaxial copper cables on page 26 Twinaxial copper cables The Veritas 5150 Appliance communicates with Ethernet networks through high speed Twinaxial copper cables If you configure the appliance to communicate with 10 Gb Ethernet networks these cables connect to the 10 25 Ethernet card in the ap...

Page 27: ...These cables are also known as Direct Attach copper cables DAC and are available in 1 meter 3 meter or 5 meter lengths 27 Veritas 5150 Appliance cables Twinaxial copper cables ...

Page 28: ...ion information Product regulatory compliance Product safety compliance Product EMC Compliance Class A Compliance Product ecology compliance Electromagnetic compatibility notices FCC Verification Statement USA ICES 003 Canada CE Declaration of Conformity Europe VCCI Japan BSMI Taiwan Veritas 5150 Appliance technical specifications The following table provides technical specifications for the Verit...

Page 29: ... core processor Processor 1 7GHz CPU speed 8 Cores 64 GB System memory currently supported DDR4 RDIMM 32 GB x 2 Memory type and configuration DIMMs Mezzanine card Yes SAS RAID card installed in a PCIe riser assembly Y N 14 5 TB Usable MSDP and AdvancedDisk storage capacity TB Up to 8 maximum 1 Gb Ethernet ports Up to 2 maximum 10 Gb Ethernet ports Height 4 32cm 1 7 approximately 1U Width 48 26cm 1...

Page 30: ...power consumption 400 watts Maximum power consumption 180 watts typical 614 BTU hr 400 watts maximum 1365 BTU hr System cooling requirement heat dissipation 100 127 VAC 200 240 VAC Operating voltage 90 Power conversion efficiency 70 dBA Acoustic noise See Environmental specifications on page 30 Environmental specifications The following table lists the environmental specifications for the Veritas ...

Page 31: ... F hour Temperature gradient See Veritas 5150 Appliance technical specifications on page 28 See Protocol standards on page 31 Protocol standards The following table provides standards with which the Veritas 5150 Appliance complies Table A 3 Veritas 5150 Appliance compliance Version Standard Intelligent Platform Management Interface Specification Second Generation v2 0 Document Revision 1 0 IPMI 2 ...

Page 32: ...compliance with your local regional rules and regulations The final configuration of your appliance product may require additional compliance testing This product is an FCC Class A device Integration of it into a Class B system does not result in a Class B device Product regulatory compliance The NetBackup appliance when correctly integrated per this guide complies with the following safety and el...

Page 33: ... 22 CISPR 32 Emissions International EN55022 EN55032 Emissions Europe EN55024 EN55035 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE European Union VCCI Emissions Japan BSMI CNS13438 Emissions Taiwan CCC Certification China Product ecology compliance Use of banned substances are restricted in accordance with world wide regulatory requirements A Material Declarat...

Page 34: ...he equipment is not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to a radio or a television reception can be determined by turning the equipment off and on the user is encouraged to try to c...

Page 35: ...ration of Conformity Europe This product has been tested in accordance to and complies with the Low Voltage Directive 2014 35 EU and EMC Directive 2014 30 EU The product has been marked with the CE Mark to illustrate its compliance VCCI Japan This is a Class A equipment Operation of this equipment in a residential environment could cause radio interference In such a case the user may be required t...

Page 36: ...system status 12 rear panel 17 serial number 8 C cables multi mode fiber optic description 25 network description 25 power description 23 twinaxial copper description 26 E environmental specifications appliance 30 I I O configuration ethernet card 18 19 21 I O configuration continued SAS tape out adapter 22 P processor type 7 protocol standards Veritas 5150 Appliance 31 R RAID levels 7 T technical...

Reviews: