![Verilink DIDCSU 2912 Manual Download Page 10](http://html1.mh-extra.com/html/verilink/didcsu-2912/didcsu-2912_manual_1004285010.webp)
DIDCSU 2912 Overview
1-4
Verilink DIDCSU 2912 User Manual
The DIDCSU 2912 does the necessary cross-connections to ensure
that the local area network signal from Building 1 terminates (or
drops) at Building 2, the video circuit is added (inserted), and the
outgoing data stream is sent on to Building 3.
1. Video data from Building 1 is destined for Building 3 but,
because there is no direct connection, is sent to Building 2
over a network line. The node at Building 2 cross-connects the
video data to timeslots on the network line that links Building
2 and Building 3. The video circuit arrives at Building 3.
(Bypass)
2. LAN A in Building 1 uses timeslots on the network line to
Building 2 for transmitting and receiving data from LAN B.
(Drop)
3. LAN C in Building 2 uses timeslots on the network line to
Building 3 for transmitting and receiving data from LAN D.
(Insert)
Components
Hardware components of the DIDCSU 2912 system include:
•
DIDCSU front module
•
Connector interface modules (CIMs)
•
CIM 29010 and 29011 (T1 CIMs)
•
CIM 29004, 29005, 29006, 29007, 29008, 29008LP,
29009LP, and 29009LP (E1 CIMs)
•
Universal power supplies and shelves
•
System cables
DIDCSU Front
Module
Figure 1-2
shows the front panel of the DIDCSU 2912.