- 4 -
- 5 -
1.1 Technical Specifications
Cable specification max.
1x4mm² or 2x2,5mm²
Ball pressure temperature
75°C
Pollution degree
2 (domestic use)
Type
1C
Storage temperature
-20 to +65°C
Protection class
Class II -
The product complies with the EN/IEC Standard “Automatic
electrical controls for household and similar use”:
•
EN/IEC 60730-1 (general)
•
EN/IEC 60730-2-9 (thermostat)
Produced for:
Veria ApS
Ulvehavevej 44
DK-7100 Vejle
Denmark
Fax:
+45 7488 7151
E-mail:
1. Safety Instructions
Make sure the mains supply to the thermostat is turned off
before installation.
IMPORTANT:
When the thermostat is used to control a floor heating
element in connection with a wooden floor or similar material,
always use a floor sensor and never set the maximum floor
temperature to more than 35°C.
Please also note the following:
•
The installation of the thermostat must be done by
an authorized and qualified installer according to local
regulations.
•
The thermostat must be connected to a power supply
via an all-pole disconnection switch.
•
The sensor is to be considered as live voltage. Have this
in mind if the sensor must be extended.
•
Always connect the thermostat to continuous power
supply.
•
Do not expose the thermostat to moisture, water, dust,
and excessive heat.
1.2 Safety Instructions