NS1003 Installation Guide 

Rev 1.1

WARNING Electricity is dangerous.

 Before commencing work, ensure that you read and understand these instructions and isolate 

the relevant circuit. 

This product should only be installed by a qualified electrician or heating engineer 

and should be installed 

in accordance to BS 7671 (IEE Wiring Regulations), or to another equivalent standard.

CAUTION: High Voltage Wires

The NS1003 series is designed to control a typical domestic central heating system. The Relay module 
can switch three independent channels. This would usually be the 2 Central Heating Zones and the Hot 
Water or 3 Central Heating Zones. 

The central heating channel is switched on and off in response to commands from the supplied Wireless 
Thermostat.

The Hot Water channel is switched on and off at the programmed time intervals that the user sets.

Whats in the box

Introduction

2(or 3) x Assembled Room Thermostat consisting of
 

1 x Room Thermostat

 

1 x Wall Mount

1 x Assembled Relay Module consisting of
 

1 x Control Board

 

1 x Wall Mount

 

1 X Front Cover

1 x Gateway
1 x Network Cable
1 x Power Supply
2(or 3) x Thermostat screw pack
1 x Relay Module Screw Pack
4(or 6) x Batteries

Gateway

Room Thermostat

Relay Module

Relay Module 

Screw Pack

Thermostat 

Screw Pack

Batteries Network Cable

Power Supply

Summary of Contents for NS1003

Page 1: ...module can switch three independent channels This would usually be the 2 Central Heating Zones and the Hot Water or 3 Central Heating Zones The central heating channel is switched on and off in response to commands from the supplied Wireless Thermostat The Hot Water channel is switched on and off at the programmed time intervals that the user sets Whats in the box Introduction 2 or 3 x Assembled R...

Page 2: ...t this may have on the radio signal is extremely important The signal will travel between units in a straight line and will degrade both with distance and much more importantly objects that it has to pass through The Relay Module needs to connect to the Wireless Internet Gateway The Thermostat needs to connect to EITHER the Wireless Internet Gateway OR the Relay Module It will automatically select...

Page 3: ...l between the Relay Module and Gateway needs to travel through three walls a staircase and various kitchen objects including Units Oven and Fridge Kitchen Boiler Relay Module Gateway Thermostat With a few simple changes we have vastly improved the signal The Relay Module is positioned away from metal objects The Gateway is positioned centrally between the Thermostat and Relay Module The Room Therm...

Page 4: ...ower Light and a Flashing Amber or Green centre light The Radio light may be Amber or Green depending on whether other units are switched on If the Middle light is not on then the device does not have a valid connection to our Web Servers Try the following Move our device to a different port Some routers only have a single 10Mbps port Try all the ports especially port 1 and port 4 Do you have a va...

Page 5: ...his unit is designed for fixed wiring only Wire the unit up following the appropriate circuit schematic for your heating system type ensuring that all wires are securely held and that no bare copper is visible outside the connector block For ease of wiring we recommend 1mm2 cable although 1 5mm2 can also be used All wiring should conform to the current IEEE wiring regulations When replacing an exi...

Page 6: ...er to the wiring diagrams below and or the Wiring Conversions on the last page After the wiring has been completed Push the control board assembly into place and secure using the 4 screws Before putting on the front cover we suggest that you test the unit for correct operation fig 1 S Plan Plus Programmer fig 2 Combi Boiler Three Zone Programmer ...

Page 7: ...RNING be aware of any buried cables before drilling Install two AA Alkaline batteries Supplied into the back of the room thermostat and ensure that the display is illuminated It is easiest to start the two securing screws off before placing it on the wall however do ensure that these screws do not protrude inside the room thermostat Carefully locate the room thermostat over the wall mount The room...

Page 8: ...ll for heat on the HW circuit Check that the boiler has fired up and any zone valves have moved to their appropriate positions Press the button again to turn the channel off Testing the Central Heating The CH light should be green On the Thermostat repeatedly press the S key to cycle between the modes until ON is displayed Then press and hold the key to raise the target temperature several degrees...

Page 9: ... Internet Gateway Press the pairing button on the back of the gateway The RF light will flash amber Long press the two outside buttons until all three lights start flashing then short press the two outside buttons To Pair the Thermostat to the Internet Gateway Press the pairing button on the back of the gateway The RF light will flash amber Press and hold the M S keys on the Thermostat for 5 secon...

Page 10: ...nnel 3 DRAYTON INVEMSYS MITIME T742R N L 1 2 3 Assumes HW is on Channel 3 RELIANCE WATER CONTROLS RW3 N L 4 6 1 3 Only compatible if nothing wired into existing terminals 2 5 DANFOSS FP735Si N L 1 ON 2 ON 3 ON Only compatible if nothing wired into existing terminals 1 OFF 2 OFF HORSTMANN CHANNELPLUS H37XL N L 1 3 6 5 Only compatible if nothing wired into existing terminals 2 4 Please note If there...

Reviews: