6
Monitor ISM/xL™ Hardware Guide
22-0375 rev1.1
No Commands (Simple Access)
Door Mode
<Login>
Notes
Card Only
<card>
If a UID/PIN is entered, it will be ignored
Card & PIN
<card> <pin>
UID is not required since the card
automatically identifies the <uid>
Card or UID/PIN
<card> or <uid> <pin>
UID/PIN Only
<uid> <pin>
If card is presented, it will be ignored.
<uid> – User ID
With Commands
Door Mode
<cmd> <Login>
Notes
Card Only
<cmd> <card>
If a UID/PIN is entered, it will be ignored
Card & PIN
<cmd> <card> <pin>
Card badging must always be done before
the PIN entry.
Card or UID/PIN
<cmd> <card> or
<cmd> # <uid> <pin>
Pressing “#” is required between the
command and uid/pin entry.
UID/PIN Only
<cmd> # <uid> <pin>
Pressing “#” is required between the
command and uid/pin entry. (Note
<cmd> # <pin> in PIN Only systems)
<cmd> – Command
NOTES:
<login> requires your <card> OR alternatively, your uid/pin.
E.g. <3 digit UID> <4 digit PIN>. Leading zeros cannot be omitted in UID or PIN.
Example 1: Arm area using card – enter < 3 card >
Example 2: Work late for 3 hours using uid/pin – enter < 6 3 # 001 1234 > for user 001 with pin 1234
Example 3: Access area without using card – enter < 001 1234 > for user 001 with pin 1234.
Using Duress Pin at Arming Station
•
A Duress Pin (reversing last 2 digits of a user’s pin entered on the keypad to transmit a potential hold-up
condition) can be used at an Arming Station if the duress feature has been enabled in the System Group.
LED Indicators
Work Late LED
•
Turns on if the area the Arming Station is assigned to is scheduled.
•
Turns on solid 15 minutes before scheduled closing time.
•
Does not operate if the area is not scheduled.
Door State LED
•
Solid red if the door is locked.
•
Solid green if the door is unlocked.
•
Flashing red during disarming if there had been an alarm in the area.
Armed LED
•
When activated, armed LED only stays on for the duration of the area’s Entry/Exit Delay during the following area
arming state changes.
–
Momentarily solid green when the area is disarmed to OFF.
–
Momentarily solid red when the area is armed to STAY.
–
Momentarily flashing red when the area is armed to Fully ON.
Arming Station Internal Buzzer Indications
•
Entry/Exit tones same as LCD keypad.
•
Fire Siren – intermittent tone.
•
Burglary Siren – steady tone.
•
Bad Command Entry – double short beeps.
•
Command accepted – single long beep.
•
Unauthorized to perform command – double long beep.