![Verderflex Dura 10 Operating Manual Download Page 17](http://html1.mh-extra.com/html/verderflex/dura-10/dura-10_operating-manual_1003793017.webp)
Dura 5 - 35
4.0v-06.2013
17 | Page
6.2.2
Switching off (Refer to → 6.1.3)
WARNING
Risk of injury due to hot pump parts!
Use personal protective equipment when carrying out
any work on the pump.
NOTE
Damage to hose due to sediments!
If the pumped liquid crystallizes, polymerizes or solidifies
–
Flush the hose
–
Make sure that the flushing liquid is compatible with
the pumped liquid.
6.3
Shutting down the pump
Take the following measures whenever the pump is
shut down:
Pump is
Measure
shut down
Take measures according to the
pumped liquid (→ Table 6
Measures depending on the
behaviour of the pumped liquid).
...dismounted
Isolate the motor from its power
supply and secure it against
unauthorized switch-on.
...put into
storage
Follow t
he storage instructions (→
8 Storage).
Tab. 5
Measures to be taken if the pump is shut down
Behavior of
the pumped
liquid
Duration of shutdown (depending
on process)
Short
Long
crystallized or
polymerized,
Solids
sedimenting
Flush the
pump.
Flush the
pump,
remove the
hose.
Solidifying
non-corrosive
Heat up or
empty the
pump
Empty the
pump
Solidifying
corrosive
Heat up or
empty the
pump
Empty the
pump.
Treat the
pump with
preservative.
Liquid,
non-corrosive
–
–
Liquid,
corrosive
Empty the
pump
Empty the
pump
Treat the
pump with
preservative.
Tab. 6
Measures depending on the behavior of the
pumped liquid
Summary of Contents for Dura 10