Rev 1.1 Cod. 00.009.126
26
STRUCTURE OF THE MAIN MENU
3sec
Press the ENTER / MENU button for 3 seconds to enter
programming.
Use the ▼ button to move the cursor to the relevant
submenus. Press ENTER to enter the submenu.
If you want to esc programming and return to measurement,
press the
ESC
button for 3 seconds.
The
Set up
menu allows choosing:
The type of measure (pH or Rx), the Language, the display contrast, the safety Password, the activation or deactivativation
of the Enable input (dosing enable) and of the peristaltic hose breaking sensor.
The
Dosage
menu allows choosing:
the type of dosage among Manual, Proportional and ON-OFF.
The
Calibration
menu allows:
Calibrating the pH or RX probe.
The
Utility
menu allows choosing:
to schedule or not the Delay On, the overdosage TAL alarm, the type of functioning of the flow sensor, to use or not a
PT100 temperature probe and finally to Restore the factory programming of the parameters and the factory probe
calibration.
The
Relay
menu allows choosing:
the operation of the alarm relay (N.O or N.C), whether to include or exclude from the relay signal the various types of alarm
(Delay On, TAL, Flow, UR-OR, Stand by, Level, Enable, Hose break.).
MENU SET UP
3sec
Press the
ENTER/MENU
button for 3 seconds to enter
programming.
Select by the cursor the menu
SET up
and press
ENTER.
Use the ▼▲ buttons to move the cursor to the submenus.
Press
ENTER
to enter the submenu.
If you want to esc programming and return to measurement,
press the
ESC
button for 3 seconds.
IMPORTANT NOTE:
Enable and Brok. Hose sensor are optional. If on your pump they are not present you can not access the
respective submenus and in the menu will appear: