Technical Data
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 psi (0.86 MPa, 8.6 bar)
Air pressure operating range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-125 psi (0.14-0.86 MPa, 1.4-8.6 bar)
Fluid displacement per cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.17 gal. (0.64 liters)
Air consumption at 70 psi (0.48 MPa, 4.8 bar), 20 gpm (76 lpm) . . . . . . . . . . . . . . . 25 scfm
Maximum values with water as media under submerged inlet conditions at ambient temperature:
Maximum air consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 scfm
Maximum free-flow delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 gpm (189 lpm)
Maximum pump speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 cpm
Maximum suction lift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ft (4.9 m) dry, 29 ft (8.8 m) wet
Flooded volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.375 gal. (1.42 liters)
Maximum size pumpable solids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8 in. (3.2 mm)
Recommended cycle rate for continuous use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 - 140 cpm
Recommended cycle rate for circulation systems. . . . . . . . . . . . . . . . . . . . . . . . . . . 20 cpm
Sound Power*
at 70 psi (0.48 MPa, 4.8 bar) and 50 cpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 dBa
at 100 psi (0.7 MPa, 7.0 bar) and full flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 dBa
Sound Pressure**
at 70 psi (0.48 MPa, 4.8 bar) and 50 cpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 dBa
at 100 psi (0.7 MPa, 7.0 bar) and full flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 dBa
Operating temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see page 32
Air inlet size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 npt(f)
Fluid inlet size
Aluminum (
VA25(HE)AA
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 in. npt(f) or 1 in. bspt
Plastic (
VA25(HE)PP
,
VA25(HE)CC,
and
VA25(HE)KP
) . . . . . . . . . . . . . . . . . 1 in. raised face ANSI/DIN flange
Hastelloy (
VA25(HE)HC
) and Stainless Steel (
VA25(HE)SA, VA25(HE)SC,
and
VA25(HE)SP
). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 in. npt(f) or 1 in. bspt
Fluid outlet size
Aluminum (
VA25(HE)AA
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 in. npt(f) or 1 in. bspt
Plastic (
VA25(HE)PP
,
VA25(HE)CC,
and
VA25(HE)KP
) . . . . . . . . . . . . . . . . . . . . . 1 in. raised face ANSI/DIN flange
Hastelloy (
VA25(HE)HC
) and Stainless Steel (
VA25(HE)SA, VA25(HE)SC,
and
VA25(HE)SP
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 in. npt(f) or 1 in. bspt
Weight
Aluminum (
VA25(HE)AA
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 lb. (10.5 kg)
Hastelloy (
VA25(HE)HC
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 lb. (18.6 kg)
Polypropylene and Conductive Polypropylene (
VA25(HE)PP
and
VA25(HE)CC
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 lb. (8.2 kg)
PVDF(
VA25(HE)KP
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 lb (11.8 kg)
Stainless Steel
with conductive polypropylene center (
VA25(HE)SC
) . . . . . . . . . . . . . . . . . . 36.3 lb. (16.5 kg)
with polypropylene center (
VA25(HE)SP
) . . . . . . . . . . . . . . . . . . . . . . . . . . . 37.3 lb. (16.9 kg)
with aluminum center (
VA25(HE)SA
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.4 lb. (18.8 kg)
Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus the pump’s material of construction
VA25(HE)AA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aluminum
VA25(HE)HC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hastelloy
VA25(HE)PP
and
VA25(HE)CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene
VA25(HE)KP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PVDF
VA25(HE)SA, VA25(HE)SC,
and
VA25(HE)SP
. . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel