SYSTEM INSTALLATION
B001032
CONNECT TO THE NMEA 2000® NETWORK
Connect the sensor and the Link Up gateway with the 3-pin
connector (Hirschmann 3way 1.2 SealStar FA Connector).
Now interface the Link Up gateway to the NMEA 2000®
backbone through the dedicated plug.
Please ensure to tighten the M12 connector by screwing it onto
its counterpart, so to preserve the water tightness.
A drop cable is not needed unless the total length of the Link
Up device is not enough to reach the NMEA 2000® backbone. In
this case it is possible to extend the total length by using one of
the accessory drop cables.
Please note that NMEA 2000® does not allow drop cables
longer than 6 meters.
Refer to the NMEA 2000® standard for a proper network
design.
If power from the NMEA 2000® network is received, the green
LED on the Link Up housing
will start flashing (see “LED
notifications”).