12
Operation and maintenance, Discfilter HSF2600 - 2,3 series with PFLC
4. START UP AND OPERATION
4.1 Check procedures during start-up
1. Check that the drive unit cover is installed correctly.
2. Set the mode selector to the HAND position (see F in Figure 4.2)
3. Set the main power switch to the ON (1) posi-
tion (see I in Figure 4.2)
4. Start drum rotation on the operator panel
main menu (see Figure 4.1 and Figure 4.2).
5. Open the water supply a little so that the
water can slowly run into the filter drum. Make
sure that the difference in water level between
the inside and outside of the filter drum does
not exceed 450 mm (see section 4.2.1). If the fil-
ter cloth becomes clogged, it may be necessary
to fill the filter basin with water from an exter-
nal source or to remove a filter panel and allow
unfiltered water to fill the filter basin.
6. When the water level inside the filter tank is above the pump suction pipe (or, if a CRK or MTR
pump has been installed, the pump), the pump must be started by pressing “Start” on the ope-
rator panel main menu (see Figure 4.1). NOTE Also read section 2.7 (Safety instructions).
7. If the water level inside the filter tank reaches the overflow wall, set the mode selector to either
REMOTE or AUTO (see section 4.2).
8. Open the water supply fully.
If the filter is operated using automatic level control, it may be necessary to calibrate the level
sensor in order for the filter to be run optimally (see “Automation manual HSF2600”).
Figure 4.1 Main menu on electrical cabinet operator panel.