Products are in-line centrifugal VKP mini fans enclosed in
a metal case for mounting in round ventilation stacks. Fans
are designed for wall and ceiling mounting, intake or extract
ventilation in domestic, public and industrial premises. Fans
are also applicable for construction projects of multi-storey
buildings where they can be used as forced-draft fans
connected to variable air volume (air change, ventilation)
system.
Each set contains:
1. Fan - 1 pc;
2. Screws with dowels - 4 pcs;
3. Manual;
4. Packing box.
Fans are compatible with 3 1/8 inches (80mm), 3 15/16
inches (100mm), 4 15/16 inches (125mm), 5 7/8 inches (150
mm) diameter ducts.
Different variants of wall and ceiling mounting of vertical and
horizontal fans are shown on Fig. 1-3. The process of fan
mounting with the use of a bracket together with four screws
and dowels is shown on Fig. 4-8. The process of ventilation
stack attachment is shown on Fig. 9-12. Air flow direction
should match the direction of an arrowhead placed on the fan
case.
Input: 120V AC 60Hz.
Fans are designed for continuous operation without
disconnection from network. Scheme of fan connection to the
power network is shown on Fig. 13. To connect the fan to the
power network it is necessary to:
- shut off the power network (Fig. 14);
- remove the cover from the terminal box (Fig.15);
- remove the clamping bar (Fig. 16);
- lay out the cables through the terminal box lug, remove the
insulation from the cables ends for ¼ of an inch (6-7mm)
length, connect them to proper terminals up to the stop of
insulation and fix with screws (Fig.17);
- place back the clamping bar, tighten up the lug and install
the cover on the terminal box (Fig.18).
Protection rating from access to dangerous parts and
water penetration for fans IPX4. Fans can be
operated at ambient temperatures between -13 ° F and +95
... +149 ° F (for the details, please, see the manufacturer's
catalog).
Fan construction is constantly being improved, that is why
some models can differ slightly from those described in this
manual models.
Recylcle at the end of unit's service l
Do not dispose of with other trash.
ife.
WARRANTY
Production meets standard operating requirements in
the territory of the USA and Canada.
Manufacturer guarantees normal operation of the unit
for 60 months from the date of resale, subject to the
compliance with transport, storage, mounting and
operation rules.
If proof of sales date is absent, warranty period is
calculated from the production date.
In case of failure due to faulty equipment warranty
period, the consumer has the right to exchange it.
The unit can be exchanged at the following address:
Bodor Vents, LLC
11013 Kenwood Road Cincinnati, Ohio 45242
Phone: (513)348-3853
e-mail: [email protected]
Manufacturer is not responsible for damages resulting
from misuse of the unit or gross mechanical alteration.
Owner of the unit must follow the guidelines set forth
in the manual.
Fan surfaces need to be cleaned of dirt and dust regularly
by using a soft, wet cloth and mild detergent (Fig. 19-22).
Do not allow liquids to come in contact with the electric
motor. Wipe surfaces dry after cleaning.