5

www.ventilation-system.com

TECHNICAl DATA

TECHNICAl DATA

Solo RA1-35-9 P

Solo RA1-35А-9 P

Speed

I

II

I

II

Voltage [V/50 Hz] 

1~230

1~230

Power [W] 

1.36

1.89

1.43

1.92

Total unit current [A] 

0.031

0.034

0.032

0.034

Air flow [m

3

/h]

30

46

23

35

Filters 

G3

G3

Transported air temperature [°C] 

from -15 up to 50

from -15 up to 50

Sound pressure level at 3 m distance [dBA]

27

32

27

32

Outdoor noise attenuation [dBA] 

40

40

Heat recovery efficiency [%] 

≤ 85

≤ 75

Ingress protection

IP24

The unit is designed for indoor application with the ambient temperature ranging from -15 °C up to +50 °C and relative humidity up to 97 %.
The ventilator is rated as a class II electric appliance.
Ingress protection rating against access to hazardous parts and water ingress is IP24.
The unit design is constantly being improved, thus some models may be different from those described in this manual.

oVERAll DIMENSIoNS [MM]

150

150

ø106

30

305-380

Summary of Contents for Solo RA1-35-9 P

Page 1: ...Solo RA1 35 9 P Solo RA1 35 9 P Single room reversible energy recovery ventilator USER S MANUAL...

Page 2: ...r s manual carefully prior to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical...

Page 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Page 4: ...VENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN The unit is rated for continuous operation Transported air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substanc...

Page 5: ...ce dBA 27 32 27 32 Outdoor noise attenuation dBA 40 40 Heat recovery efficiency 85 75 Ingress protection IP24 The unit is designed for indoor application with the ambient temperature ranging from 15 C...

Page 6: ...into the ventilator Prevents contamination of the regenerator Outer ventilation hood Prevents direct ingress of water and foreign objects into the ventilator Distance ring Ensures distance between th...

Page 7: ...the foam wedges included in the delivery set The telescopic air duct end must protrude for the distance A that enables installation of the outer ventilation hood The distance A is stated in the mounti...

Page 8: ...n unit to its original position and fix it with a screw using a screwdriver CONNECTION TO POWER MAINS AND CONTROL DISCONNECT THE UNIT FROM POWER MAINS PRIOR TO ANY OPERATIONS THE UNIT MUST BE CONNECTE...

Page 9: ...ur screws retaining the ventilation unit then pull it out of the air duct Consequently remove all elements of the ventilator 1 Clean the filters as they get clogged but not less than once in three mon...

Page 10: ...er transportation at low temperatures allow the unit to warm up at room temperature for at least 3 4 hours POSSIBLE REASONS ANDTROUBLESHOOTING Problem Possible reasons Troubleshooting When switching o...

Page 11: ...not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismoun...

Page 12: ...12 Solo RA1 35 A 9R www ventilation system com...

Page 13: ...13 www ventilation system com...

Page 14: ...14 Solo RA1 35 A 9R www ventilation system com...

Page 15: ...delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The Solo RA1 ___________________ unit has been connected to power mains pursuant to the requireme...

Page 16: ...V132EN 04...

Reviews: