Vents Bucket Fan 1055 User Manual Download Page 9

9

Fig. 7 

CONTROLLER WIRING AND INSTALLATION

•  The following is for the installation of one controller for one fan. Contact VENTS US if 

you need to operate two or more fans with one controller.

•  Refer to Figure 7 for electrical connections.
•  Use 18 AWG or greater wire. 
•  It is important that the controller be properly grounded for eff ective fan operation and 

personnel safety.

•  Always install the controller in sight of the fan it controls.
•  CAUTION: Incorrectly installed fan(s) and/or controller(s) may damage the equipment 

and void the warranty.

RED

SPEED CONTROLLER

BOX FOR SPEED CONTROLLER 

 (pre-installed by user)

TO POWER SOURCE

WHITE

WHITE

From Fan

GREEN

GREEN

BLACK

BLACK

RED

~

120 VAC 60 Hz

~

120 VAC 60 Hz

Summary of Contents for Bucket Fan 1055

Page 1: ...BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 Bucket Fan Whisper 420 Bucket Fan Whisper 1055 Bucket Fan Whisper 1460...

Page 2: ...DUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION KEY EXAMPLE 3 SIZE RANGES 3 SAFETY REQUIREMENTS 4 MOUNTING AND INSTALLATION GUIDELINES 5 BUCKET FAN PARTS 7 MAINTENANCE 8 WIRING THE FAN 8 TROU...

Page 3: ...rom the registers at the ceiling to occupant level DESIGNATION KEY EXAMPLE Bucket Fan 420 air destratification fan producing 420 CFM Bucket Fan Whisper 420 air destratification fan with isolated casin...

Page 4: ...s inside the unit that can damage the motor and or impeller blades Misuse of the Bucket Fan and or any unauthorized design alterations or modifications voids the war ranty VENTS US assumes no liabilit...

Page 5: ...ate the impeller by hand to ensure it turns smoothly Mounting The Bucket Fan comes with a set of Hanging Safety Cables with Gripples The set consists of two Gripples and two cables with a toggle on on...

Page 6: ...ggle into the top hole on the handle Attaching the Safety Cable 1 Insert the cable into one of the openings in the Gripple 2 Place the cable over the I beam truss or other attaching structure at a 400...

Page 7: ...he destratificator is equipped with a single phase asynchronous motor with an external rotor and an axial impeller The motor is equipped with built in thermal protection enabling its automatic restart...

Page 8: ...aces dry Also clean the inside of the metal case while you are at it Re attach the grille to the case Electrical wiring should only be done by a qualified electrician Warranty will not cover equipment...

Page 9: ...greater wire It is important that the controller be properly grounded for effective fan operation and personnel safety Always install the controller in sight of the fan it controls CAUTION Incorrectl...

Page 10: ...sed in diverse applications A minimum speed adjustment is provided to allow independent control of the minimum speed setting Minimum speed adjustment ensures motor runs with sufficient torque to preve...

Page 11: ...ive environment Avoid storing the fan in an area where it may be hit by a forklift where it will have to be moved a number of times etc Black Full Voltage Motor Red Red L2 L1 Black Variable Voltage 24...

Page 12: ...improper maintenance or repair other than by VENTS US faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products is not covered The dur...

Reviews: