Prior to Installation:

Read and understand this entire manual. Should you have any questions before, during, or after 
installation please call your seller or contact VENTS at 888-640-0925 or [email protected].

Check the product for any damage that may have occurred during shipping.

Rotate the impeller by hand to ensure it turns smoothly.

Mounting

The Bucket Fan comes with a set of Hanging/Safety Cables with Gripples. The set consists of two 
Gripples and two cables with a toggle on one end.

NOTE:

 The Hanging and Safety Cables are the exact same, so there is no need to worry about which 

one is which.

NOTE: 

The toggle ends are the ones that are inserted into the handle.

WARNING: 

Both the Hanging and Safety cables MUST be installed as directed.

Fig. 2 . Attaching the Bucket Fan with the Hanging Cable and Gripple.

Summary of Contents for Bucket Fan 1055

Page 1: ...BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 Bucket Fan Whisper 420 Bucket Fan Whisper 1055 Bucket Fan Whisper 1460...

Page 2: ...DUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION KEY EXAMPLE 3 SIZE RANGES 3 SAFETY REQUIREMENTS 4 MOUNTING AND INSTALLATION GUIDELINES 5 BUCKET FAN PARTS 7 MAINTENANCE 8 WIRING THE FAN 8 TROU...

Page 3: ...rom the registers at the ceiling to occupant level DESIGNATION KEY EXAMPLE Bucket Fan 420 air destratification fan producing 420 CFM Bucket Fan Whisper 420 air destratification fan with isolated casin...

Page 4: ...s inside the unit that can damage the motor and or impeller blades Misuse of the Bucket Fan and or any unauthorized design alterations or modifications voids the war ranty VENTS US assumes no liabilit...

Page 5: ...ate the impeller by hand to ensure it turns smoothly Mounting The Bucket Fan comes with a set of Hanging Safety Cables with Gripples The set consists of two Gripples and two cables with a toggle on on...

Page 6: ...ggle into the top hole on the handle Attaching the Safety Cable 1 Insert the cable into one of the openings in the Gripple 2 Place the cable over the I beam truss or other attaching structure at a 400...

Page 7: ...he destratificator is equipped with a single phase asynchronous motor with an external rotor and an axial impeller The motor is equipped with built in thermal protection enabling its automatic restart...

Page 8: ...aces dry Also clean the inside of the metal case while you are at it Re attach the grille to the case Electrical wiring should only be done by a qualified electrician Warranty will not cover equipment...

Page 9: ...greater wire It is important that the controller be properly grounded for effective fan operation and personnel safety Always install the controller in sight of the fan it controls CAUTION Incorrectl...

Page 10: ...sed in diverse applications A minimum speed adjustment is provided to allow independent control of the minimum speed setting Minimum speed adjustment ensures motor runs with sufficient torque to preve...

Page 11: ...ive environment Avoid storing the fan in an area where it may be hit by a forklift where it will have to be moved a number of times etc Black Full Voltage Motor Red Red L2 L1 Black Variable Voltage 24...

Page 12: ...improper maintenance or repair other than by VENTS US faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products is not covered The dur...

Reviews: