![Ventrac LW450 Operators Manual & Parts Drawing Download Page 20](http://html.mh-extra.com/html/ventrac/lw450/lw450_operators-manual-and-parts-drawing_1002364020.webp)
LW450 SETUP INSTRUCTIONS
Setup - 20
37. Place the SDLA access cover into position and
fasten loosely with 2) flange bolts at the back.
Fasten loosely at the top with 2) 1/4 x 1” flange
bolts (S) included in the installation hardware.
38.
S
S
S
T
Place the right frame insert panel (T) into posi-
tion and fasten with 2) 1/4 x 1” flange bolts (S)
through the right frame insert panel and the SDLA
access cover.
39. Tighten the bolts for the SDLA access cover.
40. Route the wire harness underneath the cab and
front frame upper cross member and over the
frame cross tube into the wire harness area.
41. Locate the 2 position MP630 connector with a
red wire (labeled A-002) and a black wire (A088).
Remove the cap and connect to the cab harness.
NOTE: save this cap to plug the connector if the
cab is removed from the power unit.
42. Reinstall the canvas cover under the seat.
43. If the seat was removed for cab installation, rein-
stall the seat onto the seat plate. Lower the seat
down to the operating position.
44. Install the 30 amp circuit breaker
U
into slot 2 (U) in the rear fuse
panel and reinstall the fuse
panel cover.
45. Install the floor mats (V) in the foot rest area of
the frame panels. Tuck the bottom outside cor-
ner of each floor mat under the nut on the frame
end panels to help hold the mat down in place.
Make sure the right floor mat does not interfere
with the operation of the foot pedal control. The
rear tab on the right floor mat bends up next to
the hydraulic quick couplers to keep the mat
from sliding to the left and interfering with the
foot pedal control.
46.
V
V
Turn the battery disconnect switch to the On
position.
47. Test the function of the cab lights and controls
along with the function of any accessory kits
installed on the weather cab.