Page 4

L108 1213A

6” Outlet

Vent

Hole

3 ¼”

Electrical

Centerline

of Hood

Wall Side

1 ¾”

1 3⁄8”

5 ¼”

Electrical

1 ¾”

Centerline

of Hood

8” Outlet

Vent

Holes

5 ¼”

5 ½”

Wall Side

8” Outlet

6” Outlet

5 ¼”

Wall Side

Vent

Holes

Centerline

of Hood

Electrical (2)

5 ½”

7 5⁄16”

1 7⁄8”

7 5⁄16”

1 ¾”

11”

11”

5 ½”

5 ½”

Wall Side

5 ¼”

1 ¾”

Electrical (2)

8” Outlet

Vent

Holes

8” Outlet

Centerline

of Hood

Installation Details Continued

Connection Diagram (40 3/8”- 58 3/8” Widths)

Connection Diagram (46 3/8”- 64 3/8” Widths)

900 CFM B200 Dual & B100 Single Blower

(Top View)

1200 CFM Double B200 Dual Blowers     

(Top View)

4)  Remove the hood from its packaging and place the back of the hood on the floor or countertop in front of the wall 

where it will hang. Save the trim kit and hardware for step 10.

5)  Remove the shipping tape that is securing the E-Z Clean shield(s) inside the hood. Remove the E-Z Clean shield(s) by 

lightly pulling it toward the front of the hood. Gently close the back draft damper(s) from the top side of the hood. To 

remove the blower housing(s), unsnap the suitcase latches (one on each side of the housing). The housing(s) should 

be pulled forward and gently “tipped” to clear the blower wheel(s) and then out of the hood.

Warning:  Make sure power is off and locked at the service disconnecting 

means on the service panel during installation.

300 CFM B100 Single Blower

(Top View)

600 CFM B200 Dual Blower

(Top View)

Connection Diagram (28 3/8”- 40 3/8” Widths)

Connection Diagram (28 3/8”- 52 3/8” Widths)

6)  Remove the three screws retaining the blower motor(s). Unplug 

and remove the motor(s), taking care not to damage the blower 

wheel(s). It is not necessary to remove the blower wheel from 

the motor.

Summary of Contents for VP526

Page 1: ...nto wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire ...

Page 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use...

Page 3: ...of the liner allowing room for the transition if applicable If back venting the elbow s should be installed so that the non crimped end s are on the inside the collar s of the exhaust outlet s If a transition is used install duct down to the location of the transition outlet plus 1 This will allow the transition to engage 1 inside of duct Consult the connection diagrams next page for further detai...

Page 4: ... for step 10 5 Remove the shipping tape that is securing the E Z Clean shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear...

Page 5: ...sly removed from the packaging in Step 4 11 Install the trim piece for the back side of the liner provided in the liner trim kit by hooking one side under the bottom edges of the back countersunk washers Snap the trim piece over the top of the countersunk washers by applying pressure upward and toward the liner wall Repeat this process for the side trim pieces provided in the liner trim kit Note I...

Page 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Reviews: