background image

Operating and Assembly Instructions

AI 200

AI 201
AI 202
AI 203

Extractor Hood

Summary of Contents for AI201100

Page 1: ...Operating and Assembly Instructions AI 200 AI 201 AI 202 AI 203 Extractor Hood...

Page 2: ...1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions...

Page 3: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Page 4: ...iance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operat...

Page 5: ...to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and...

Page 6: ...2 m LK 011 026 for ceiling heights of 2 42 2 74 m LK 011 036 for ceiling heights of 2 74 3 00 m Installation accessories for circulating air mode Stainless steel design ventilation duct LK 010 126 for...

Page 7: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Page 8: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 9: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Page 10: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Page 11: ...al filter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated The activated charcoal filter KF 001 010 is available through yo...

Page 12: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Page 13: ...e from the cooking surface to the bottom edge of the extractor hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the extractor h...

Page 14: ...essible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct LK 010...

Page 15: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Page 16: ...t the minimum distance between the hob and the extractor hood is maintained 600 mm for an electric hob and 650 mm for a gas hob Circulating air mode only there are four brackets which fix the circulat...

Page 17: ...ust be on the same side as the control panel after installation Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe...

Page 18: ...magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first chimney duct...

Page 19: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 D 81739 M NCHEN Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com en...

Reviews: