background image

Page 6

L108 1213A

VENTING

ACCESSORIES

6” RECTANGULAR DUCT PIPE

MODEL

DIM

VP507

6” x 8 ½”

24”

8 ½”

6”

ROUND DUCT PIPE

MODEL

DIM

VP500

VP501

VP502

6” Round

7” Round

8” Round

36”

6”

7”

8”

3 ¼” RECTANGULAR DUCT PIPE

MODEL

DIM

VP504

VP505

VP506

3 ¼” x 10”

3 ¼” x 12”

3 ¼” x 16”

30”

10”

12”

16”

3 ¼”

OFFSET L & R TRANSITION

FOR ISLAND BLOWERS

MODEL

DIM

VP542

VP543

Top Left

Top Right

8”

12”

5”

16”

SIDE VENT TRANSITION L & R

FOR ISLAND BLOWERS

MODEL

DIM

VP544

VP545

Left Side

Right Side

19”

8”

16”

5”

OFFSET KIT - RECTANGULAR

MODEL

DIM

VP550

6” Rnd to 3 ¼” x 10”

16”

11”

6”

11”

3 ¼”

10”

STANDARD ISLAND TRANSITION

MODEL

DIM

VP565

5” x 16” to 8”

8”

9”

16”

5”

CLUSTER BLOWER TRANSITION

MODEL

DIM

VP564

8” & 8” to 12”

18 ½”

12”

11 ¼”

“Y” TRANSITION

MODEL

DIM

VP517

VP518

VP551

8” & 8” to 12”

6” & 8” to 12”

6” & 8” to 10”

18”

10”

12”

3 ¼” x 10” BACK VENT ELBOW

MODEL

DIM

VP559

3 ¼” x 10”

4 ¼”

10”

14”

3 ¼”

3 ¼”

MULTI-BLOWER TRANSITION

MODEL

DIM

VP562

VP563

6” & 8” to 10”

8” & 8” to 12”

VP562 - 17 ½”

VP563 - 16 ½”

10”

12”

VP562 - 23 ¼”

VP563 - 30 ½”

3 ¼” x 10” TO 7” TRANSITION

MODEL

DIM

VP521

3 ¼” x 10” to 7”

7”

7 ½”

3 ¼”

10”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

6 ½”

VP539

VP540

VP541

6” Round

7” Round

8” Round

16 ¾”

16 ¾”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

10 ½”

VP552

VP553

10” Round

12” Round

22 ½”

20 ¾”

ADJUSTABLE ELBOW

MODEL

DIM

VP513

VP514

VP515

6” Round

7” Round

8” Round

6”

7”

8”

VP513 - 8 ½”

VP514 - 9 9⁄16”

VP515 - 10 5⁄8”

BACK/SIDE VENT ELBOW

MODEL

DIM

VP561

8” to 6” x 8 ½”

12”

6”

16”

8” Round

8 ½”

WALL LOUVER

MODEL

DIM

6”

7”

8”

8 5⁄8”

VP526

VP527

VP528

6” Round

7” Round

8” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

11”

11”

VP554

10” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

13”

13”

VP555

12” Round

Back

View

1 ½” Flange

RECTANGULAR WALL LOUVER

MODEL

DIM

3 ¼”

10”

VP538

VP560

6” x 8 ½“

3 ¼” x 10”

8 ½”

6”

1 ½”

 FLANGE

2” FLANGE

OFFSET KIT - ROUND

MODEL

DIM

VP529

6” Rnd to 7” Rnd

16”

11”

6”

7”

10 ½”

LOW PROFILE ROOF JACK

(MINIMUM 4/12 PITCH)

MODEL

DIM

10 ½”

VP552-HP

VP553-HP

10” Round

12” Round

22 ½”

20 ¾”

M1200 STANDARD TRANSITION

MODEL

DIM

VP566

21” x 8” to 10”

10”

9”

8”

21”

LOW PROFILE ROOF JACK

(MINIMUM 4/12 PITCH)

MODEL

DIM

6 ½”

VP539-HP

VP540-HP

VP541-HP

6” Round

7” Round

8” Round

16 ¾”

16 ¾”

Summary of Contents for VP526

Page 1: ...nto wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire ...

Page 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use...

Page 3: ...of the liner allowing room for the transition if applicable If back venting the elbow s should be installed so that the non crimped end s are on the inside the collar s of the exhaust outlet s If a transition is used install duct down to the location of the transition outlet plus 1 This will allow the transition to engage 1 inside of duct Consult the connection diagrams next page for further detai...

Page 4: ... for step 10 5 Remove the shipping tape that is securing the E Z Clean shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear...

Page 5: ...sly removed from the packaging in Step 4 11 Install the trim piece for the back side of the liner provided in the liner trim kit by hooking one side under the bottom edges of the back countersunk washers Snap the trim piece over the top of the countersunk washers by applying pressure upward and toward the liner wall Repeat this process for the side trim pieces provided in the liner trim kit Note I...

Page 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Reviews: