Vent-Axia Lo-Carbon Revive Installation And Wiring Instructions Download Page 8

 

D. SERVICING AND MAINTENANCE. 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT 
MUST BE ISOLATED FROM THE POWER SUPPLY DURING 
MAINTENANCE. 

 
1.  At intervals appropriate to the installation, the fan should be inspected and 

cleaned to ensure there is no build-up of dirt or other deposits.  

2.  Wipe the inlets and front face with a damp cloth until clean.

 

 

 

The fan has sealed for life bearings, which do not require lubrication. 
 
 
 
E. TROUBLESHOOTING 

 

 

1.  The fan continuously runs in boost: 

a.  Cause: 

i.  The room is damp or recently redecorated. 

ii.  The humidity set point is set too low. 

b.  Solution: 

i.  If the room is damp or has recently been decorated, it could 

take up to 2 weeks for the humidity levels to stabilise. Please 
leave the fan to dry out the room and after this period the fan 
should run normally.  

ii.  The humidity set point could be set too low. Adjust the 

humidity set point to a higher setting. (Section C) 
 

2.  The fan does not boost when the humidity is high: 

a.  Cause: 

i.  The humidity set point is set too high. 

b.  Solution: 

i.  Adjust the humidity set point to a lower setting. (Section C) 

 

3.  Water is dripping out of the fan when installed in a ceiling: 

a.  Cause: 

i.  This is caused by condensation forming on the inside of the 

ducting and dripping out of the fan inlet.  

b.  Solution: 

i.  This is normal and the fan is designed to handle condensation 

build up. However a condensation trap connected immediately 
after the fan will help to prevent water dripping into the room.  

 

 

 
 
 

Summary of Contents for Lo-Carbon Revive

Page 1: ...N Revive 7 473848 Revive 7 SELV 473849 Revive 5 473850 Revive 5 SELV 473851 Revive 473852 Revive SELV 473853 Revive Intermittent 478367 Revive SELV 478368 Intermittent PLEASE READ INSTRUCTIONS IN CONJ...

Page 2: ...cting all poles having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with...

Page 3: ...NSFORMER SELV Models only 1 The transformer must not be installed in a shower cubicle or enclosure It must be sited away from direct sources of water spray and out of reach 1 5m of a person using a fi...

Page 4: ...dels only MUST be surface mounted to allow air to freely circulate around the unit When installed in a loft void it MUST NOT be enclosed or covered with insulation The fan is a class ll double insulat...

Page 5: ...ion type settings kitchen or bathroom and ducted or window wall The difference between bathroom and kitchen mode is shown above the boost speeds are higher for kitchen applications If the fan is insta...

Page 6: ...usted after commissioning as a pass code is required to access the menu This can be set in the menu to any 3 digit hexadecimal combination If the lock feature is enabled when a button is pressed the d...

Page 7: ...to move the display to the next data set Data Logger Menu When the display is rotated the decimal point will no longer display eg 055 represents 5 5KWh Data Examples Text scrolling from right to left...

Page 8: ...orated it could take up to 2 weeks for the humidity levels to stabilise Please leave the fan to dry out the room and after this period the fan should run normally ii The humidity set point could be se...

Page 9: ...1 with no trickle facility The fan is internally fused Fig 3 Continuous trickle with boost facility The fan is internally fused Fig 1 Continuous trickle with boost via pull cord The fan is internally...

Page 10: ...els Fig 6 Continuous trickle with boost facility via LS or internal pullcord SELV models Fig 4 Continuous trickle with pullcord boost SELV models N L 1 Phase Supply 220 240V 50Hz FUSE Switched Fused S...

Page 11: ...the screw at the bottom of the grille 2 Pull the grille clear of the screw and lift away Circuit board cover DO NOT REMOVE Control Board Display INCREASE Value REDUCE Value MODE Button Note Revive 7...

Page 12: ...to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your...

Reviews: