Comfort mode
Comfort mode changes how the fan boosts. Normally the fan will go into boost as soon as an
LS input is detected and over run for the set period when LS is disconnected. In comfort mode
the fan will not boost until the LS has been on for 5 minutes, preventing nuisance noise. After 5
minutes of LS being on the fan will run in boost as long as LS is on and for the over run time
after LS is switched off. If the LS is switched off before 5 minutes the fan will not boost. This
mode does not affect the pullcord operation, pulling the pullcord will still activate boost.
Lock feature (Revive 5,Revive 7 & Revive Intermittent models)
The lock feature will prevent the unit from being adjusted after commissioning as a pass code is
required to access the menu. This can be set in the menu to any 3 digit hexadecimal
combination.
If the lock feature is enabled; when a button is pressed the display will show, – – –. At this point
enter the three digit code by first pr or – until the first digit is correct then press MODE
to move to the next digit. Repeat until the code is entered and press MODE to enter the
commissioning menu. If the code is entered incorrectly, wait until the screen switches off then
press any button to begin again
.
Setup example
> >
> >
> >
> >
Mode button being pressed to scroll through menu. This set up is for a kitchen, in a through the wall
installation with 15 minute boost timer, 60% rH set point and not in comfort mode.
> >
> >
> >
Mode and up buttons pressed to change the setting to Bathroom and ducted modes
>
>
>
>
>
>
Up button pressed to change boost time from 15 to 18 minutes
+
+
+
+
+
X