disconnection under over voltage category III, the instructions state
that means for disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
M.
Ensure the grille is fully engaged onto the fan chassis using all the
clips.
INSTALLATION
IMPORTANT:
The fan should only be used in
conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1.
For panel/ceiling mounting the fan should be
installed into a closed duct protected by an
exterior air grille that must comply with the
standard requirements of your country to prevent
access to the fans impeller.
2.
Cut a 105mm diameter hole for 100mm fans.
3.
Push the two clips on the bottom of the fan and
pull the grille away from the chassis.
4.
Using the built in spirit level bubble as an aid.
Mark the screw centres through the holes in the
fan back plate. Drill, plug and screw into position.
5.
After installation, ensure impeller rotates freely
and the shutters can open.
6.
Replace the grille and ensure the clips reactivate.
WALL MOUNTING
1.
For wall mounting either cut a 115mm diameter hole for 100mm fans, through the wall and insert the wall
sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both ends into
position flush with the wall faces.
2.
Push the two clips on the bottom of the fan and pull the grille away from the chassis.
3.
Using the built in spirit level bubble as an aid. Mark the screw centres through the holes in the fan back
plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres positioned
downwards. (Note:- The grille must comply with the standard requirements of your country to prevent
access to the fans impeller. The wall kit used in this installation should provide a minimum ducting length
of 100mm from the fans back plate to the inside of the external grille).
4.
After installation, ensure impeller rotates freely and the shutters can open.
5.
Replace the grille and ensure the clips reactivate.
WIRING
WARNING:
THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
IMPORTANT
The fan should only be used in conjunction with fixed wiring.
The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm
2
.
Cable entry can only be made from the rear of the fan.
The extraction fan is suitable for connection to 220-240V 50Hz supply.
The fan is a class ll double insulated product and
MUST NOT
be earthed.
Open up the internal cover to access
the spirit level bubble
Spirit level used
only for cosmetic
help. Not essential
for the normal
working of the fan.