1. Select and follow the appropriate wiring diagram. (Fig. 1 or 2)
2. Check all connections have been made correctly and ensure all terminal connections are securely fastened.
3. Ensure the impeller rotates and is free from obstructions.
SETUP
WARNING:
THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
MUTE 100 BN -
(fig. 1, 3 and 4)
Basic - Remote or light switch operation.
2 Speed options selectable at install.
MUTE 100 TN* -
(fig. 2, 3 and 4)
Overrun timer - adjustable 5-30min.
2 Speed options selectable at install.
MUTE 100 HTN* -
(fig. 2, 3 and 5)
Humidity Timer - Humidity controlled (40-90% R.H.) with fixed 15min. timer overrun.
2 Speed option selectable at install.
*All timer versions require a third switch live wire for the timer to work.
SERVICING AND MAINTENANCE
WARNING:
THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED
FROM THE POWER SUPPLY DURING MAINTENANCE.
1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no
build-up of dirt or other deposits.
2. Wipe the inlets and front face with a damp cloth until clean.
The fan has sealed for life bearings, which do not require lubrication.