Safety (Continued)

THIS MANUAL SHOULD REMAIN WITH THE HOOD

FOR FUTURE REFERENCE

CAUTION

TO REDUCE THE RISK OF FIRE, AND TO PROPERLY EXHAUST 

AIR, BE SURE TO DUCT EXHAUST AIR OUTSIDE. DO NOT VENT 

EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS, OR 

INTO ATTICS, CRAWL SPACES, OR GARAGES.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO 

NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL 

DEVICE.

CAUTION

FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO 

EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND 

VAPORS.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

Summary of Contents for Air Recovery System

Page 1: ...tanding reputation because of our commitment to performance quality and reliability The Importance of Cooking Ventilation The main purpose of cooking ventilation is to capture the by products of cooki...

Page 2: ...s a tag to the service panel C Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction D Su...

Page 3: ...inguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit...

Page 4: ...DE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES WARNING TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE S...

Page 5: ...The single speed motor is either off or on and is not controlled by the SensaSource heat sensor or the red switch Black Switch White Switch This switch controls the lights LOW level lighting position...

Page 6: ...ainless Steel Magic Vent A Hood part number SS64 Follow all label instructions Do not polish across the grain or in circles B Blower Unit WARNING To reduce the risk of personal injury be sure the powe...

Page 7: ...C Blower Wheel WARNING To reduce the risk of personal injury be sure the power is turned off in the hood before removing the grease pan Regular cleaning of the grease pan should prevent grease accumul...

Page 8: ...handle hex wrench A may be obtained from Vent A Hood to accomplish this Vent A Hood part number AW101 There is a small set screw on the side of the hub of the wheel that tightens up against a flat spo...

Page 9: ...over opening and slide the canister out of the duct cover Replace activated carbon media or discard filter with household refuse 4 Install new filters following the installation procedures in the ARS...

Page 10: ...nt that is being used Whenever possible hoods should overlap the cooking equipment by at least three inches on each side The hood should also project out to the front edge of the front burners Finally...

Page 11: ...noise This may be caused by the blower wheel coming in contact with the blower housing Refer to Hood Cleaning Section C for blower wheel installation details NOTE If smoke still enters the kitchen aft...

Page 12: ...allation D Incidental or consequential damage E Commercial application F Misapplication or modification of or to any part of the Vent A Hood product Warranty To make a warranty claim contact the deale...

Reviews: