20
Setup Steps
Second Stage on Until Deadband (Setup Step 38) -
Specifies whether second
stage will turn off at first stage deadband or remain on until the room temperature
demand is satisfied. Choose between Deadband or Setpoint.
Third Stage on Until Deadband (Setup Step 39) -
Specifies whether third stage
will turn off at second stage deadband or remain on until the room temperature
demand is satisfied. Choose between Deadband or Setpoint.
Fourth Stage on Until Deadband (Setup Step 40) -
Specifies whether fourth
stage will turn off at third stage deadband or remain on until the room temperature
demand is satisfied. Choose between Deadband or Setpoint.
Press the SETUP button, then press MODE repeatedly until the
desired setup step appears. Use the WARMER or COOLER buttons
to make selection. Press MODE to advance to the next step.
Press/hold MODE to go backwards to prior steps. Press SETUP to
leave the setup screens.
WARMER
COOLER
MODE
SETUP
Programmable Fan (Setup Steps 41-44)
Fan Program
(Setup Step 41)
This feature allows the fan to be programmed to turn on automatically for a
specified amount of time during the day. If this feature is set to ON, the next three
steps will appear.
Minutes of Fan Runtime Per Hour
(Setup Step 42)
This setting specifies the number of minutes (0 - 60, in increments of 5) that the
fan will run at the top of each hour.
Fan Program Start Time
(Setup Step 43)
This setting specifies the hour of each day when the programmable fan feature
will start.
Fan Program Stop Time
(Setup Step 44)
This setting specifies the hour of each day when the programmable fan feature
will stop.
NOTE: Setting the Stop Hour equal to the Start Hour will cause the fan to run 24
hours a day.