background image

Electric TV Lift, TS600B 

 

11 

 

8. RF/IR remote learning 
 

If the control box does not respond when pushing the emitter buttons, they need to be paired. 
 

o

  Push the Learner button on the control box for less than 1 sec. 

o

  The red LED will turn on 

o

  Push one of the RF/IR emitter buttons 

o

  The red LED will start flashing 

o

  When the red LED stops flashing, the units now are coded together with a unique code 

o

  To abort a learning operation push the Learner button once more. The red LED will turn 

off and the control box is back into normal operation mode. 

 
 

9. Declaration of conformity 

 
 

We hereby declare, under our sole responsibility that the following products:  

-

 

VENSET TV-lift product type 

TS600B

 

is in accordance with 

-

 

Directive 2006/42/EF of the European Parliament and of the Council of 17 May 2006 on 
machinery and on changes of directive 95/16/EF 

With reference to the above please be aware that: 

-

 

the TV-lift is considered a partly completed machinery and 

-

 

the TV-lift may not be used until it has been assembled and installed  
according to the instructions. 

 
  

Manufacturer: 

VENSET A/S 
Industrivej 23 
DK-6900 Skjern 
Denmark 
Tel: +45 9735 4611, Fax: +45 9735 4631

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

The information in this document is subject to change without notice. 

Summary of Contents for TS600B

Page 1: ...cluded 4 Control box 5 Installation 6 Adjusting the stroke length of the lift 7 Operation modes 8 RF IR remote learning 9 Declarations of conformity WARNING WARNING FAILURE TO COMPLY WITH OR OBSERVE ALL ASSEMBLY SAFETY AND OPERATION INSTRUCTIONS AND WARNINGS REGARDING THE USE OF THIS PRO DUCT MAY RESULT IN SERIOUS BODILY INJURY No 338390 4 ...

Page 2: ...rom liquid contact or spillage To avoid damaging the power supply and power cord do not put anything on it or place it where it could become damaged Unplug the lift in the following conditions When the power cord or plug is damaged or frayed If the lift or power supply has been exposed to rain or water or any liq uid contamination whatsoever If the lift exhibits a distinct change in performance in...

Page 3: ...aterials and weights Steel black powder coated Weight 6 2 kg Max working loads 12 kg by standard installation 15 kg peak load Duty cycle 10 by 50 of working load or max 2 min continuously Operation Rocker switch Voltage 100 240 VAC 50 60Hz Main dimensions TS600B mm ...

Page 4: ...arts included Lift unit 1 Rocker switch 2 Rubber washer 3 Control box 4 Power supply 5 AC input wire country configured 6 Lift unit 1 AC input wires coun try configured 6 Power supply 5 Rocker switch 2 Control box 4 Rubber washer 3 ...

Page 5: ...Electric TV Lift TS600B 5 4 Control box Learner button Blue light Red light IR sensor input TV lift output DC power input Rocker switch input ...

Page 6: ...side of your mounting board with suitable length Allen screws when using these holes you will not need to raise the lift to secure to the upper brackets Place a rubber washer 3 be tween each bracket and the mounting surface 6 Mount rocker switch 2 in an easy location by cutting a ø30 hole and pressing the switch into place Secure excess wire to keep away from moving parts 7 Plug the power cord 6 i...

Page 7: ...ft by lifting a hinged lid must be calculated in the total load and the total including the TV or any item being lifted and the VESA bracket must not exceed 12kg which is the maxi mum working load Always adjust the travel position height range of the lift so that the lid lifter is touching the lid or within 3mm of the lid underside when the lift is closed otherwise the auto stop system may operate...

Page 8: ...ers downwards to increase the height of the lifts lowest position 2 5mm Allen key required Make sure to tighten the screws properly Adjust these 2 end stop sliders upwards to decrease the maxi mum height of the lifts upper posi tion 2 5mm Allen key required Make sure to tighten the screws properly ...

Page 9: ...en Momentary or Latching behavior for both the rocker switch and RF IR remote When Momentary mode is chosen the TS600B only operates as long as the rocker switch or a button of the RF remote is held down In latching mode only a single push is required to start or stop operation of the TS600B Operation Mode Jumper M L Off Rev Aux Jumper position Upside up momentary default setting Set Set Set Set U...

Page 10: ...entary Set Set Set Open Open Horizontal momentary Open Set Set Open Open If the TS600B is mounted horizontal the jumper Rev can be used to select if the TS600B pull out jumper Rev set or pull in jumper Rev open when pressing the up button of the RF IR re mote The momentary mode is not useable for the optional IR remote ...

Page 11: ...box is back into normal operation mode 9 Declaration of conformity We hereby declare under our sole responsibility that the following products VENSET TV lift product type TS600B is in accordance with Directive 2006 42 EF of the European Parliament and of the Council of 17 May 2006 on machinery and on changes of directive 95 16 EF With reference to the above please be aware that the TV lift is cons...

Reviews: