Intended use and general instructions
The product is suitable for pumping liquids (sea water, fresh water,
brackish water, chlorinated water and other non-aggressive liquids) at a
temperature of + 2 ° C to + 40 ° C. A list of the parts in contact with the
medium to be pumped can be found in the appendix, for non o.a.
Media please ensure the compatibility with the specified components
before use.
The product can deliver both clear and polluted water up to a particle size of 1mm.
When used in dirty water, regular cleaning and the use of a pre-filter to protect the
pump are required. Especially the internal flushing channel has to be cleaned.
Abrasive ingredients increase wear - damage resulting from this is excluded from the
warranty.
The pump is not self-priming and must therefore always be mounted below the water
level.
Please always observe the generally applicable national and international regulations
during installation.
The maximum working pressure must not exceed 2.5 bar.
Prior to storage, the product must be thoroughly cleaned with fresh water and suitable
cleaning agents (such as Abyzz Pump Cleaner), otherwise residues may accumulate
in the pump.
When using, please make sure that the intake duct is adequately protected, otherwise
animals or objects will get into the pump to avoid damage.
When laying piping, make sure there is sufficient compensation for temperature
fluctuations in the pipe sections.
Use sufficient pipe diameter, we recommend minimum diameter of 50mm at the
suction and 40mm at the pressure side.
The product has a dry run warning. If the pump is dry running
over 50%
of speed the
controller gives an alarm. The pump has to be switched off immediately to make sure
no permanent damage is done. The user is responsible for the pump not running dry.
8