Electrical connection:
The Abyzz driver requires a voltage of 100 ... 240V / 50 ... 60Hz.
The connection must be made to a suitable, properly installed earthed socket, which is
protected by a circuit breaker in accordance with DIN VDE 0100T739 (residual current
circuit breaker). We recommend that you do not connect more than one controller to a
supply line (16A fuse).
The driver has a fuse for fire protection inside. This is to be exchanged exclusively by
the service. Inside the device are no user-servicable elements.
Installation of pump
The Abyzz pump can be operated submerged to a depth of 2 meters or in a dry
position.
The mounting position has to be horizontally as a standard.
For all other possible mounting positions the user is responsible for the safe operation
of the pump. It has to be made sure, that the pump is always filled with the medium
completely. Abyzz cannot be held responsible for damages to the pump, which result
from inappropriate mounting other than the recommended standard.
Make sure there is a free, unobstructed water supply at the connection line of the
suction side and protect the inlet with a suitable sieve to keep coarse particles (sand,
threads from filter wadding or similar) away from the impeller. When piping you should
make sure to install at least 50cm of straight piping on the suction side, so that the
water can flow in straight. These measures optimize the efficiency and ensure a clear
noise reduction. For the highest possible efficiency, please use sufficient pipe
diameters for larger pipe systems (Recommended: suction side 50mm (2"), pressure
side 40mm (1 1/4“)).
When using adhesive fittings, be sure to use an adhesive suitable for the material
(PVC).