background image

INST

ALLA

TION MANUAL

INST

ALLA

TION

14

Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.
Use the illustration below to identify your kitchen cabinet type.

EZ1 one-person installation system

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as 
the range hood width. If the cabinet is greater than 1/2” wider than the range hood width, please 
use the standard installation method.

1 ] 

Use the proper template for vertical OR horizontal disharge (included) for placement of 
ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a 
duct access hole, only cut the hole for electrical wiring. 

If replacing a hood and plan to use 

the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.

2 ]  

Measure and mark the hood center line on cabinet bottom.

3 ]  

Align the center line on template with the hood center line marked on the bottom of the 
cabinet, placing the edge (where indicated) of the template against back wall. When using 
with framed cabinet for vertical exhaust installation, fold over rear edge of template equal 
to the depth of the cabinet frame at the wall (use graduations on template, 

C

 locations on 

template). Tape the template in place.

 

NOTE: When facing the installation, 

A

 and 

B

 (on template) must be at right.

CABINET FRONT

C

L

A

B

Apoyar este borde contra la pared de atrás

Place this edge against back wall

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT RECTANGULAIRE

C

ONDUIT ROND DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO RECTANGULAR

C

ONDUCTO REDONDO

DE

 7 

PULG

.

O

Appuyer ce bord au mur arrière

Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK WHERE INDICATED

FOR THE APPROPRIATE SIZE DUCT OPENING

M

ARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON

LE FORMAT DE CONDUIT UTILISÉ

T

ITLE TO BE TRANSLATED IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

P

C

CABINET FRONT

C

L

A

B

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT RECTANGULAIRE

C

ONDUIT ROND DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO RECTANGULAR

C

ONDUCTO REDONDO

DE

 7 

PULG

.

O

Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK WHERE INDICATED

FOR THE APPROPRIATE SIZE DUCT OPENING

M

ARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON

LE FORMAT DE CONDUIT UTILISÉ

T

ITLE TO BE TRANSLATED IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN CABINET BOTTOM

)

CENTER LINE

F

OLD TEMPLATE ALONG GRADUATED

SCALE WHEN INSTALLING TO FRAMED

CABINET

.

B

VERTICAL EXHAUST 

DUCTING

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN WALL

)

CENTER LINE

C

L

A

B

Place this edge against
cabinet bottom.
Appuyer ce bord contre le bas
de l’armoire.
Apoyar este borde contra
la base del armario.

HORIZONTAL EXHAUST

T

T

= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

= 3¼” x 10”
= 3¼” x 14”

RECTANGULAR DUCTING

= 3¼ po x 10 po
= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

MARK WHERE INDICATED

FOR THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON

LE FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

B

ess hole center
wer hood
wer hood

HORIZONTAL EXHAUST 

DUCTING

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) 
and the EZ1 one-person installation system (using included template and brackets).
For the standard installation, go to page 19.

FRAMED CABINET

FRAMELESS CABINET

Summary of Contents for VBNLB1 Series

Page 1: ...Serial number 99045659 006G RANGE HOOD Series VBNLB1 INSTALLATION USE AND CARE MANUAL WWW VENMAR CA ...

Page 2: ...Installation 8 21 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 13 Prepare the Hood Location 14 EZ1 One Person Installation 14 16 Install the Hood EZ1 Bracket 17 18 Standard Installation 19 Install the Hood Standard Installation 20 Connect the Wiring 21 Install the Filters 21 Wiring Diagram 22 Service Parts 23 24 Wa...

Page 3: ...ufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local cod...

Page 4: ...uisher and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage a...

Page 5: ...ice that activates the blowers when an abnormally high heat level is detected while the blowers are activated During the Heat Sentry activation this device takes control of the blowers and set them on MEDIUM speed while all dots under the blower icon blink However the lights can be still controlled The blowers will remain on MEDIUM speed until the heat is back to normal they then return to the spe...

Page 6: ...e elevated temperatures of cooking offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs MASTER ON OFF Press this button to turn on the ligths and the blowers at the last saved intensity When either lights or blowers are ON pressing this button will memorize the current blower speed and lighting level prior to shut...

Page 7: ...ucted recirculation filters FAN WHEELS The center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wi...

Page 8: ... Installations Only SOFFIT 24 MIN 30 MAX ABOVE COOKING SURFACE CABINET 3 X 10 OR 3 X 14 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 3 X 14 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 30 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 3 x 14 or 7 round or horizontally 3 x 10 or 3 x 14 ...

Page 9: ...rrière Utiliser ce gabarit pour marquer vos repères ne pas tenter de découper le trou pour le conduit à travers le gabarit NOTE Les découpes incluent le jeu nécessaire à l installation elles ne doivent pas être du format exact des conduits Use esta plantilla para crear marcados no trate de cortar el agujero del conducto a través de la plantilla NOTA To be translated in Spanish MARK WHERE INDICATED...

Page 10: ... finger cup remove the grease filters from the hood by pushing down and tilting filters out 1 2 3 4 5 6 7 4 Remove and set aside the damper flap A Remove the blower cover plate in grey Using a 11 32 nutdriver or socket remove the lock nut retaining the flange of the cover plate to the inner back of hood see inset Remove the cover plate 7 retaining screws using a Phillips screwdriver then set the b...

Page 11: ... tie wrap Discard the tie wrap EZ1 BRACKETS PARTS BAG LOCATION 6 Remove Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood For knockout removed from back of hood install an appropriate strain relief 1 2 diameter not included For knockout removed from top of hood the strain relief will be installed later ELECTRICAL POWER CABLE KNOCKOUT ...

Page 12: ...rk 8 Remove 3 x 14 vertical or 3 x 14 horizontal knockout plate as appropriate for your ducting method see FIGURES 1 A and 1 B 3 X 14 VERTICAL KNOCKOUT PLATE 3 X 14 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 3 X 14 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Assemble the 3 x 14 frame removed in step 2 with the damper flap removed in step 4 by following the inst...

Page 13: ...ate off center ductwork the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Attach 3 x 10 Damper A...

Page 14: ...3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the exact size of ducting 3 po x 10 po 3 po x 14 po CONDUIT RECTANGULAIRE CONDUIT ROND DE 7 PO OU 3 pulg x 10 pulg 3 pulg x 14 pulg CONDUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Utiliser ce gabarit pour m...

Page 15: ...ews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location on template 5 Use a sharp pencil or 1 8 drill bit to mark the locations for the appropriate duct access holes 16 locations for 7 round duct or 4 corner locations for rectangular duct Remove the temp...

Page 16: ...line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align outside edge of the bracket to marked line keeping the rear end edge leaning on the wall Use a pencil to mark 3 holes Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood scre...

Page 17: ...le into the hood through the strain relief previously installed in step 6 on page 11 4 Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT HOLES C and D While holding the hood go to step 6 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood tighten an appropriate strain relief 1 2 diameter not included to the power cable ...

Page 18: ...arts bag Insert two 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws included in parts bag Insert two 2 screws per side in the slots as shown in insets on illustration below 9 Attach power cable to the hood using the strain relief WOOD SCREWS METAL SCREWS ...

Page 19: ... 5 12Ǭ 12Ǭ 9 3 X 10 HORIZONTAL DUCTING 4 16 8 DIA HOLE 7 IN ROUND DUCT ACCESS HOLE 7 IN ROUND DUCT ACCESS HOLE 1 Ǫ 9 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM 12Ǭ 12Ǭ REAR HOOD MOUNTING SCREWS 2 WOOD SHIMS RECESSED BOTTOM CABINETS ONLY 7 IN ROUND VERTICAL DUCTING VERTICAL DUCT ACCESS HOLE 5 5 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY C...

Page 20: ...ds wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cabinet using two 2 no 8 x 5 8 round head wood screws included in parts bag Insert one 1 screw per side in the slots as shown below Attach power cable to the hood using the strain relief 4 Connect ductw...

Page 21: ...cal wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally MOTORS GROUND WIRE HOUSE POWER CABLE GROUND SCREW 1 2 3 4 5 6 7 Install the Filters Ducted Installation Only Re install grease filters removed in step ...

Page 22: ...e W W W W Transformer Heatshrink W R BK LED 2 1 LED 2 1 The control board is viewed with the connectors on the opposite side of the board BK Line Neutral Ground 120 VAC Supply W BN BN W BK O G Y 1 2 3 5 4 6 R R C R Y BK BK Low speed capacitor 1 2 3 5 4 6 C Low speed capacitor COLOR CODE BK BL BN BN W G Y BLACK BLUE BROWN BROWN WHITE GREEN YELLOW O R W Y ORANGE RED WHITE YELLOW REF 990729480_REV A ...

Page 23: ...8 LCD CONTROL WITH SCREWS 1 1 S97020796 WIRE HARNESS WITH AUTOTRANSFORMER AND FUSE 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCL 4 CLIPS 1 1 S97020470 EASY INSTALL KIT INCLUDING HARDWARE...

Page 24: ...60 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCL 4 CLIPS 1 1 S97020470 EASY INSTALL KIT INCLUDING HARDWARE 1 1 ITEM NOT SHOWN B C E G I J K L M F D REPLACEMENT PARTS AND REPAIRS In order to ensure you...

Page 25: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Com...

Reviews: