background image

D o w n d r a f t   H o o d   

I n s t r u c t i o n   M a n u a l

DD925CO

Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk

Summary of Contents for DD925CO

Page 1: ...Downdraft Hood Instruction Manual DD925CO Contact Caple on 0117 938 7420 for spare parts or www caple co uk ...

Page 2: ... O NTE NT S Introduction 3 Safety Instructions 4 Dimensions 8 Installing the Extractor 9 Grease Filter Removal Installing theActivated Charcoal Filter 15 Electrical Connection 16 Remote Control 18 Cleaning the Extractor 22 Troubleshooting 23 Aftersales Service 24 Caple Contact Details 28 ...

Page 3: ...mode and ducted with outside evacuation W A R N I N G Keep these instructions for use with the appliance If the appliance should be sold or passed on to others make sure that the instructions are passed on with it We thank you for taking note of these suggestions before installing and using the appliance They have been written for your personal safety and the safety of others ...

Page 4: ...ppliance is designed for normal domestic use It is not designed for commercial or industrial use or for purposes other than those for which it was designed Any consequences of or damage from incorrect installation or incorrect use of the appliance will not be covered by the manufacturer s guarantee Do not ever change or try to change the characteristics of this appliance This would be a danger Rep...

Page 5: ...d replacement of grease filters Accumulated deposits of grease are a fire hazard This appliance must not be used near hobs powered by wood or coal or in any case near hobs with power levels that could damage the appliance Never use steam or high pressure devices for cleaning your hood regulations regarding electrical safety Never use the cooker hood without the grease filters fitted The minimum di...

Page 6: ...e the right to modify their technical functional or aesthetic characteristics deriving from their upgrading In the event a downdraft is installed with an external motor for normal downdraft operation it is necessary to use an external motor made by Caple The air collected must not be conveyed into a flue used for smoke or fumes from appliances powered by anything other than electricity central hea...

Page 7: ... you purchased the product WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information to your retailer in order to receive a replacement date of purchase model and serial number Registration can also be completed online by visiting www caple co uk Ensure you keep your warranty card safe you may need to show it to Cap...

Page 8: ...tout can be connected to the hob cutout but only for electric hobs For gas hobs a minimum 50mm gap must be left beetween the edge of the gas hob and the downdraft frame NOTE The Downdraft worktop cutout can be connected to the hob cutout but only for electric hobs For gas hobs a minimum 50mm gap must be left between the edge of the gas hob and the downdraft frame ...

Page 9: ...city of 1 linear meter eg if you use no 2 x 90 elbows the length of piping should not exceed 3 meters Avoid abrupt direction changes Use a 150mm constant diameter rigid ducting pipe for the whole length or equal surface area Only use ducting approved by the standards in force The manufacturer shall not be deemed responsible for air capacity or noise problems caused by failure to comply with the ab...

Page 10: ...the traction to be positioned downwards of the product at the moment of fixing in order to have the stainless steel trim perfectly adhering with the work surface Before inserting the screws please make sure that the appliance is perfectly perpendicular with the work surface 6 If using an internal motor with the downdraft place the internal motor in the desired position with the air outlet facing e...

Page 11: ...ndraft to choose from Fig 4 8 Place the electrical box in an easily reachable area for future maintenance and service operations Fig 5 Connect the 3 connections 9 pole connector for the actuator control and safety control 4 pole connector for the neon lamp turn on and push button connector Fig 6 9 Connect the motor unit cable to the relevant connector on the electrical components box Fig 7 Fig 4 F...

Page 12: ...eference 10 Power the downdraft 11 Let the downdraft rise as described in the How the downdraft works section When the downdraft has fully risen unscrew and remove the safety locks see Fig 8 Install the metal filter cover in this location Fig 9 Fig 7 14 Fig 8 Fig 9 Fig 10 Fig 11 ...

Page 13: ... case fumes and vapour cannot be evacuated outside the appliance can be used in recirculation mode Activated charcoal filters are required for this type installation To purchase the Charcoal filters please visit www caple co uk or call our sales office on 0117 938 1900 Air recycled through the charcoal filters is recircu lated back into the kitchen thanks to a vent conveying the air in the cabinet...

Page 14: ... a qualified technician RECIRCULATED MODE In case fumes and vapour cannot be evacuated outside the appliance can be used in the recirculating mode Activated charcoal filters are required for this type of installation In case of outside air discharge installation fit a non return valve to prevent wind and back air from entering Air recycled through the charcoal filters is recirculated into the kitc...

Page 15: ...ters which are magnetically secured to the appliance by using either a hand tool or a knife edge Using the slot found in the filter sides as shown in Fig 9 The charcoal filter is installed directly on the back of the grease filter see Fig 12 Charcoal filters shall be replaced accordingly to the effective use of the Downdraft and in any case at least once every 6 months Fig 13 Fig 12 WARNING After ...

Page 16: ...ulations We decline any responsibility in case of accidents caused by a lack of ground connection or incorrect ground connection The appliance must be fed through a differential protection device RCD with a nominal residual current not exceeding 30mA If the power cord is damaged call the Caple after sales service to avoid any risk WARNING The downdraft connection to the electrical network must be ...

Page 17: ...L CONNECTION While installing the appliance and carrying maintenance operation make sure it is disconnected from the electrical network or the fuses are cut out or removed Check that Power is enough Feeder lines mains are in good condition The cable diameter complies with installation regulations ...

Page 18: ...After 10 minutes from its setup it allow the motor close the extractable unit an lights off if on Push the key again to annul this function TECHNICAL DATA Alkaline battery powered 12v mod 27A Operating frequency 433 92 Mhz Combinations 4096 Max consumption 25mA Operating temperature 20 55 C Standard con iguration If two cooker hoods radio control syste stalled in the same room or in the imm cinity...

Page 19: ...the fact that they have the same code Therefore it will be necessary to change the code of one of the radio controls Generating a new transmission code The radio control is supplied by the manufacturer with default codes stored If you want to create a new set of codes proceed as follows press and hold the UP STOP and DOWN buttons simulta neously for 2 seconds After the LEDS light up press the UP a...

Page 20: ...s for two seconds When LED s light on press buttons within 5 seconds LED s flashing 3 times indicate the procedure is completed WARNING This operation permanently deletes the preset codes LEARNING THE NEW TRANSMISSION CODE Once the transmission code is changed in the remote control unit the electronic central unit of the cooker hood must be made to set the new code in the following way Press the m...

Page 21: ...TIMING This product is equipped with intelligent electronics which include a timer device for speed controls when the air capacity exceeds 650m h Internal motor models with maximum air capacity higher than 650m h are equipped with a timer device that automatically switches the speed from 4th to 3rd speed after 6 minutes operation External motor models are equipped with remote motors that as for in...

Page 22: ...ROCEED ACCESSORY PRODUCTS TO USE External surfaces and accessories Do not use metallic scrubbers abrasive products or hard brushes To clean the external surfaces of the cooker hood and the light housing screen use only commercially avail able household detergents diluted in water Then rinse with clean water and dry with a soft cloth Active charcoal filter In the recirculation mode the active charc...

Page 23: ... during the connection phase an excessive pressure could bend the contacts The downdraft has low performance Check that The motor speed selected is sufficient for the quantity of fumes and vapours present in the room The kitchen is ventilated well enough to allow air for intake The charcoal filter is not worn out Filtering version cooker hood The air outlet channel is free and compliant with parag...

Page 24: ...aple approved engineer or similar qualified person If a problem still persists and further assistance is required please contact our Caple after sales team on T 0117 938 7420 E service caple co uk NOTE When contacting Caple Service please provide the appliance details shown on the appliance labels This information is stated on the rating label and the production date is placed on the lower side of...

Page 25: ...Instruction manual DD925CO 25 Please keep this instruction manual for future reference ...

Page 26: ...Instruction manual DD925CO 26 Please keep this instruction manual for future reference NOTES ...

Page 27: ...Instruction manual DD925CO 27 Please keep this instruction manual for future reference NOTES ...

Page 28: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...

Reviews: