9. HORIZONTAL DISCHARGE (
CONT
’
D
)
9.2 A
TTACH
THE
M
OUNTING
P
LATE
TO
THE
W
ALL
Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud.
1.
Remove the rear wall template and discard.
2.
Remove the toggle wings from the bolts.
3.
Insert the bolts into the mounting plate through the holes
designated to go into drywall and reattach the toggle
wings to 3/4” onto each bolt.
4.
Place the bottom of the mounting plate against the
horizontal line on the wall (previously drawn in step 5.4 )
and insert the toggle wings into the holes in the wall to
mount the plate.
5.
Tighten the wood screw and all bolts.
9.3 P
REPARE
T
OP
C
ABINET
You need to drill holes for the top support screws and a hole large enough for the power cord to fi t through.
1.
Read the instructions on the top cabinet template.
2.
Tape it underneath the top cabinet.
3.
Drill the holes following the instructions on the template.
4.
Remove the template and discard.
9.4 A
DJUST
B
LOWER
1.
Remove and set aside the 2 blower plate retaining
screws.
2.
Lift up the blower plate.
MO0012
19
M
OUNTING
PLATE
MO0013A
W
ALL
B
OLT
END
T
OGGLE
BOLT
T
OGGLE
WINGS
S
PACING
FOR
TOGGLES
MORE
THAN
WALL
THICKNESS
MR0011
B
LOWER
PLATE
MD0008A
S
CREW
M
ICROWAVE
BACK
S
CREW
M
ICROWAVE
TOP
WARNING
Be careful to avoid pinching fi ngers between
the back of the mounting plate and the wall.
!
WARNING
Wear safety goggles when drilling holes in the