20. OPERATION

 (

CONT

'

D

)

H

EAT

 S

ENTRY

™:

  The hood is equipped with a HEAT SENTRY thermostat. If blower is ON at a lower 

speed setting and excessive heat is detected above the cooking surface, it turns 
the blower up to third speed. When the temperature level drops to normal, the 
blower will return to its original setting. 

NOTE: When Heat Sentry is activated, the “DELAY OFF” function is inactivated.

    WARNING

!

The Heat Sentry can change the speed of the blower when excessive heat is detected 
above the cooking surface. If this situation occurs and you must stop the blower, press on 
the third speed button or on the master ON/OFF button.

D. L

IGHT

 B

UTTON

/B

ACKLIGHTING

 C

OLOR

 (D

OUBLE

 F

UNCTION

 B

UTTON

):

 

i.  This button allows three different lighting levels according to your needs. Press once for full 

intensity, twice for intensity level 

2

, and once more for nightlight. To turn off the lights, press 

once more.

 

If desired, when the lights are on, press and maintain the light button for 1 second; lights will 
be turned off.

NOTE:  When only the lights are ON to any intensity and no interaction with the hood is detected for 

a 10-second period, the 7 buttons backlighting will fade to its low intensity, acting as a night 
light feature.

 

ii.  When lights are off, pressing and holding this button for 1 second will switch the backlighting 

color from white to blue or from blue to white (default backlighting color is white) and 
memorize it. The button will flash three times to indicate that the color change has been 
made.

NOTE:  Due to the particular sensitivity of the control interface, keep the glass panel clean as dirt 

and condensation may cause erratic operation of the hood blower and/or lighting. If this 
situation occurs, wipe the glass panel and wait 90 seconds. Then, adjust the blower and/or 
lighting at your convenience.

Summary of Contents for ISPIRA IB700 Series

Page 1: ...HOMEOWNER USE AND CARE INFORMATION ON PAGES 17 TO 19 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ONLINE AT ww...

Page 2: ...high heat or when flambeing food i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fan frequently Grease should not be allowed to accumulate on fan filters or in exhaust d...

Page 3: ...L CAP MODEL 634 OR 644 ROOF CAP MODEL 639 3 X 10 WALL CAP MODEL 428 OPTIONAL 3 X 10 ELBOW UPPER DECORATIVE FLUE IC700 AND IC700ES LOWER DECORATIVE FLUE IC700 AND IC700ES MODEL 401 3 X 10 STANDARD DUCT...

Page 4: ...RK 4 5 2 PREPARE THE INSTALLATION 5 6 3 REMOVE HYBRID FILTERS 6 4 INSTALL GLASS PANEL WG MODELS ONLY 6 7 5 PREPARE THE OPENING 7 8 5 1 IC700 AND IB700 MODELS 7 5 2 IC700ES MODELS 8 6 BLOWER REMOVAL HO...

Page 5: ...s Parts sold separately Ducts elbows wall and roof caps Refer to page 3 for a complete list of venting options and model numbers Optional flue extension for 10 ft ceilings model no 19323 Glass panel f...

Page 6: ...hing them down and flipping downwards Set the filters aside HO0250 4 INSTALL GLASS PANEL WG MODELS ONLY HD0560 SCREW LOCATIONS The WG hood models decorative glass panels are sold separately and have t...

Page 7: ...et tighten the nuts completely 5 Reinstall the electrical compartment cover HD0561 GLASS PANEL STUD NUT 5 PREPARE THE OPENING CAUTION Never use a hammer and screwdriver to remove the vertical or horiz...

Page 8: ...isassemble the blower from the inner top of the hood by following the steps below It will be assembled to the inner back of the hood once the hood is mounted on the wall 5 2 IC700ES MODEL 5 PREPARE TH...

Page 9: ...7 INSTALL THE ADAPTER DAMPER HORIZONTAL DISCHARGE Mount the 3 x 10 adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct t...

Page 10: ...power at service entrance before wiring GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an...

Page 11: ...ocation Secure it to wall framing using 3 no 8 x 1 screws Using a level draw a vertical line up to the ceiling starting from the mounting bracket center HD0567A WALL STUDS FRAMING BEHIND DRYWALL 10 IN...

Page 12: ...rs into both lower drilled holes Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket and slightly pull it downward to make sure it...

Page 13: ...y from the adapter damper 14 PREPARE THE DECORATIVE FLUE IC700 AND IC700ES HO0183 LOWER FLUE REAR NOTCH 1 Remove protective plastic film covering the lower flue only 2 Peel off both corners at the top...

Page 14: ...top of the hood 1 until flue notches completely fit in hood slots 2 HO0192 HO0187 1 2 3 Slide up the upper flue until it is aligned with its mounting bracket The bracket must be inside the flue Secure...

Page 15: ...a HORIZONTAL DISCHARGE Cut out a 115 8 width x 12 depth opening in cabinet bottom b VERTICAL DISCHARGE Cut out a 115 8 square opening in cabinet bottom 3 Drill 3 holes on each side of the blower box...

Page 16: ...ood using 2 metal foil duct tape Reinstall blower by following step 12 FOR VERTICAL DISCHARGE ONLY Measure the length of metal duct required from the adapter damper to the house ductwork Slide the duc...

Page 17: ...accumulate Let plaster dust or any other construction residues reach the hood During construction renovation cover the hood to make sure no dust sticks to stainless steel surfaces WARNING Before serv...

Page 18: ...possible to lock the control interface in order to clean the glass panel To lock the control interface Press and hold this button for 2 seconds The button will light to its high intensity and flash t...

Page 19: ...for intensity level 2 and once more for nightlight To turn off the lights press once more If desired when the lights are on press and maintain the light button for 1 second lights will be turned off N...

Page 20: ...1 J10 J9 Serial Com 5 4 3 2 1 J5 Output J6 External Triac 2 3 4 5 1 2 3 4 1 2 1 2 1 2 3 4 1 2 3 1 2 YEL BLK BLK WHT WHT WHT RED RED RED BLU WHT ORG BLK WHT BLK WHT RED RED WHT BLK WHT RED GRY BRN BLU...

Page 21: ...DRIVER AND CONNECTION HARNESS 1 1 8 21189 POWER UNIT 1 1 9 09014 HOOD MOUNTING BRACKET 1 1 10 13296 ADAPTER DAMPER 1 1 11 SV19134 UPPER FLUE 1 1 12 19135 UPPER FLUE MOUNTING BRACKET 1 1 13 SV19133 LOW...

Page 22: ...enmar Ventilation ULC Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be r...

Reviews: