11.  INSTALL THE HOOD (IC700 AND IC700ES)

    WARNING

!

BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.

CAUTION

DO NOT REMOVE yet the protective plastic film covering the decorative flues (upper 
and lower).

HD0417A

L

OWER

 

HOLES

 

LOCATION

U

PPER

 

HOLES

 

LOCATION

Ø 

3/16” 

TYP

.

S

IDE

 

VIEW

1. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it 

securely engages the bracket, and slightly pull it downward to make sure it is fully engaged.

2. Level the hood.

3. Mark the position of both 

holes located inside lower 
back of hood (as shown at 
right). Also mark the position 
of 2 of the 6 available upper 
holes (one on each side). 
Remove the hood. Drill 
through both lower holes 
using a 3/16” drill bit. Insert 
the included drywall anchors 
into both lower drilled holes. 
Align the hood and center it above the hood mounting bracket. Gently lower the hood until it 
securely engages the bracket, and slightly pull it downward to make sure it is fully engaged.

NOTE: 

For horizontal discharge only

, make sure the adapter/damper enters the duct opening 

 

and seal joint from inside the hood using 2” metal foil duct tape.

4. Secure the hood to the wall using 2 no. 8 x 3/4” screws for lower holes, and 2 no. 8 x 1½ for 

upper holes.

12. REINSTALL THE BLOWER 

(HORIZONTAL DISCHARGE ONLY - IC700)

HD0563

1. Position the blower on the back wall discharge. 

Secure the blower to the hood using a 5/16” 
socket, or a Robertson or a Phillips no. 2 
screwdriver and the 4 previously removed 
screws.

NOTE: In order to ease installation, 

 

before mounting the blower, 

 

prepare the screw holes by 

 

screwing all 4 screws without 

 

the blower, then remove and 

 

mount the blower.

CAUTION

Make sure that the screws are well tightened before continuing the installation.

Summary of Contents for ISPIRA IB700 Series

Page 1: ...HOMEOWNER USE AND CARE INFORMATION ON PAGES 17 TO 19 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ONLINE AT ww...

Page 2: ...high heat or when flambeing food i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fan frequently Grease should not be allowed to accumulate on fan filters or in exhaust d...

Page 3: ...L CAP MODEL 634 OR 644 ROOF CAP MODEL 639 3 X 10 WALL CAP MODEL 428 OPTIONAL 3 X 10 ELBOW UPPER DECORATIVE FLUE IC700 AND IC700ES LOWER DECORATIVE FLUE IC700 AND IC700ES MODEL 401 3 X 10 STANDARD DUCT...

Page 4: ...RK 4 5 2 PREPARE THE INSTALLATION 5 6 3 REMOVE HYBRID FILTERS 6 4 INSTALL GLASS PANEL WG MODELS ONLY 6 7 5 PREPARE THE OPENING 7 8 5 1 IC700 AND IB700 MODELS 7 5 2 IC700ES MODELS 8 6 BLOWER REMOVAL HO...

Page 5: ...s Parts sold separately Ducts elbows wall and roof caps Refer to page 3 for a complete list of venting options and model numbers Optional flue extension for 10 ft ceilings model no 19323 Glass panel f...

Page 6: ...hing them down and flipping downwards Set the filters aside HO0250 4 INSTALL GLASS PANEL WG MODELS ONLY HD0560 SCREW LOCATIONS The WG hood models decorative glass panels are sold separately and have t...

Page 7: ...et tighten the nuts completely 5 Reinstall the electrical compartment cover HD0561 GLASS PANEL STUD NUT 5 PREPARE THE OPENING CAUTION Never use a hammer and screwdriver to remove the vertical or horiz...

Page 8: ...isassemble the blower from the inner top of the hood by following the steps below It will be assembled to the inner back of the hood once the hood is mounted on the wall 5 2 IC700ES MODEL 5 PREPARE TH...

Page 9: ...7 INSTALL THE ADAPTER DAMPER HORIZONTAL DISCHARGE Mount the 3 x 10 adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct t...

Page 10: ...power at service entrance before wiring GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an...

Page 11: ...ocation Secure it to wall framing using 3 no 8 x 1 screws Using a level draw a vertical line up to the ceiling starting from the mounting bracket center HD0567A WALL STUDS FRAMING BEHIND DRYWALL 10 IN...

Page 12: ...rs into both lower drilled holes Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket and slightly pull it downward to make sure it...

Page 13: ...y from the adapter damper 14 PREPARE THE DECORATIVE FLUE IC700 AND IC700ES HO0183 LOWER FLUE REAR NOTCH 1 Remove protective plastic film covering the lower flue only 2 Peel off both corners at the top...

Page 14: ...top of the hood 1 until flue notches completely fit in hood slots 2 HO0192 HO0187 1 2 3 Slide up the upper flue until it is aligned with its mounting bracket The bracket must be inside the flue Secure...

Page 15: ...a HORIZONTAL DISCHARGE Cut out a 115 8 width x 12 depth opening in cabinet bottom b VERTICAL DISCHARGE Cut out a 115 8 square opening in cabinet bottom 3 Drill 3 holes on each side of the blower box...

Page 16: ...ood using 2 metal foil duct tape Reinstall blower by following step 12 FOR VERTICAL DISCHARGE ONLY Measure the length of metal duct required from the adapter damper to the house ductwork Slide the duc...

Page 17: ...accumulate Let plaster dust or any other construction residues reach the hood During construction renovation cover the hood to make sure no dust sticks to stainless steel surfaces WARNING Before serv...

Page 18: ...possible to lock the control interface in order to clean the glass panel To lock the control interface Press and hold this button for 2 seconds The button will light to its high intensity and flash t...

Page 19: ...for intensity level 2 and once more for nightlight To turn off the lights press once more If desired when the lights are on press and maintain the light button for 1 second lights will be turned off N...

Page 20: ...1 J10 J9 Serial Com 5 4 3 2 1 J5 Output J6 External Triac 2 3 4 5 1 2 3 4 1 2 1 2 1 2 3 4 1 2 3 1 2 YEL BLK BLK WHT WHT WHT RED RED RED BLU WHT ORG BLK WHT BLK WHT RED RED WHT BLK WHT RED GRY BRN BLU...

Page 21: ...DRIVER AND CONNECTION HARNESS 1 1 8 21189 POWER UNIT 1 1 9 09014 HOOD MOUNTING BRACKET 1 1 10 13296 ADAPTER DAMPER 1 1 11 SV19134 UPPER FLUE 1 1 12 19135 UPPER FLUE MOUNTING BRACKET 1 1 13 SV19133 LOW...

Page 22: ...enmar Ventilation ULC Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be r...

Reviews: