Venmar CONNAISSEUR CC32I SERIES Installation Instructions Manual Download Page 2

2

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.

  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.

  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.

 Installation work and electrical wiring must be done by 

qualified personnel in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.

  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards such as 
those published by the National Fire Protection Association 
(NFPA) and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code 
authorities.

5.

  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.

  Ducted fans must always be vented outdoors.

7.

  Do not use this unit with any solid-state speed control device.

8.

  To reduce the risk of fire, use only metal ductwork.

9.

  This unit must be grounded.

10.

 

When applicable, local regulations comprise more 
restrictive installation and/or certification requirements, 
the aforementioned requirements prevail on those of this 
document and the installer agrees to conform to these at his 
own expenses.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)

  Never leave surface units unattended at high settings. Boilovers 

cause smoking and greasy spillovers that may ignite. Heat oils 
slowly on low or medium settings.

b)

 Always turn power pack ON when cooking at high heat or 

when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambé).

c)

  Clean ventilating fans frequently. Grease should not be allowed 

to accumulate on fan, filters or in exhaust ducts.

d)

  Use proper pan size. Always use cookware appropriate for the 

size of the surface element.

1.

  For indoor use only.

2.

 For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

3.

  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.

  Your hood motor has a thermal overload which will automatically 

shut off the motor if it overheats. The motor will restart when it 
cools down. If the motor continues to shut off and restart, have 
the hood serviced.

5.

 The minimum hood distance above cooktop must not be 

less than 24” (30” over a gas range). A maximum of 30” 
above cooktop is recommended for best capture of cooking 
impurities.

6.

  Two installers are recommended because of the large size and 

weight of this unit.

7.

  To reduce the risk of fire and to properly exhaust air, be sure to 

duct air outside — Do not exhaust air into spaces within walls 
or ceiling or into attics, crawl space or garage. 

8.

  This product is equipped with a thermostat which may start 

blower automatically. To reduce the risk of injury and to prevent 
power from being switched on accidentally, switch power off at 
service panel and lock or tag service panel.

9.

  Because of the high exhausting capacity of this hood, you 

should make sure enough air is entering the house. Open a 
window close to or in the kitchen.

10.

 To reduce the risk of fire and electrical shock, the Venmar 

Connaisseur CC32I Series models should only be installed 
with their own built-in blowers.

11.

 

Please read specification label on product for further 
information and requirements.

    WARNING

CAUTION

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE 
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE 
THE FOLLOWING*:

1.

  SMOTHER FLAMES with a close-fitting lid, cookie sheet or 

metal tray, then turn off the burner. BE CAREFUL TO PREVENT 
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, 
EVACUATE AND CALL THE FIRE DEPARTMENT.

2.

  NEVER PICK UP A FLAMING PAN — You may be burned.

3.

  DO NOT USE WATER, including wet dishcloths or towels — 

This could cause a violent steam explosion.

4.

  Use an extinguisher ONLY if:

 

A.

 You own a Class ABC extinguisher and you know how to 

operate it.

 

B.

 The fire is small and contained in the area where it started.

 

C.

 The fire department has been called.

 

D.

 You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

    WARNING

Summary of Contents for CONNAISSEUR CC32I SERIES

Page 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 AND 14 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Page 2: ...oper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and va...

Page 3: ...SUPPLIED WITH 09025 NON DUCT KIT 8 ROUND STANDARD DUCT 8 ROUND ADJUSTABLE ELBOW OPTIONAL MODEL 643 8 ROUND WALL CAP MODEL 401 STANDARD 3 X 10 DUCT CC32I SERIES RANGE HOOD SINGLE BLOWER SUPPLIED WITH...

Page 4: ...he unit it is recommended to wear safety glasses and gloves 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION Non duct kit model 09025 is required for a non ducted installation 2 2 DUCTED INSTALL...

Page 5: ...TH HOOD 30 WIDTH HOOD VERTICAL DISCHARGE OR NON DUCTED INSTALLATION HORIZONTAL DISCHARGE HD0391 1 2 4 CHOOSE THE OPENING VERTICAL DISCHARGE OR NON DUCTED INSTALLATION Using a Robertson or a Phillips n...

Page 6: ...ed to receive the adapter Before performing the installation make sure the adapter fits easily in the duct If this hood replaces another one please note that the location of the air exhaust can vary f...

Page 7: ...ounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be pl...

Page 8: ...of its screws Drill the 3 screw holes using a 3 16 drill bit Insert the included drywall anchors into the drilled holes 1 per hole Secure the upper flue bracket to the wall using 3 no 8 x 3 4 screws...

Page 9: ...s assemble the 8 round adapter to the lower plenum plate HD0382 A A Carefully align the upper plenum plate central notch with the line traced in step 9 see inset at right and place it flush to the cei...

Page 10: ...Y VERTICAL DISCHAGE Plug hood power cord into the outlet Slide a 8 metal round duct over the adapter damper on the hood Use metal foil duct tape to seal the joint HJ0037 NON DUCTED INSTALLATION Plug h...

Page 11: ...move protective plastic film covering the lower flue only then just peel off the plastic film covering both top corners of the upper decorative flue Position the lower flue rear notches down the ones...

Page 12: ...the plenum sides using 2 no 8 x 1 4 screws included per side NOTE Ceiling not shown in illustration to ease understanding HA0079 ALL INSTALLATIONS Remove protective plastic film covering the upper fl...

Page 13: ...metal filters in the dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions but this will not affect fi...

Page 14: ...B START STOP SPEED SELECTION SWITCH Press the switch corresponding to the desired blower speed from 1 for low speed to 4 for high speed The chosen switch will light To turn off the blower press once m...

Page 15: ...e the product will be repaired or replaced at Venmar s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar...

Page 16: ...OUND CHARCOAL FILTERS 2 PER KIT 1 17 09016 ROUND CHARCOAL FILTER SUPPORT 2 18 09017 8 ROUND METAL FLEXIBLE DUCT 1 19 08543 8 ROUND ADAPTER 1 20 18509 LOWER PLENUM PLATE 1 21 18508 UPPER PLENUM PLATE 1...

Reviews: