Venmar CONNAISSEUR CC32I SERIES Installation Instructions Manual Download Page 12

12

16. INSTALL DECORATIVE FLUE (ALL INSTALLATIONS) 

(CONT'D)

D

UCTED

 

INSTALLATION

Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be 
inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 3/8” screws (included). 
See illustration beside.
NOTE: Duct not shown in illustration to ease understanding.

HO0140

U

PPER

 

FLUE

 

MOUNTING

 

BRACKET

F

RONT

 

VIEW

U

PPER

FLUE

N

ON

-

DUCTED

 

INSTALLATION

Slide the upper flue up to the ceiling. The plenum must be inside the flue. Secure the upper 
flue to the plenum sides using 2 no. 8 x 1/4” screws (included) per side.
NOTE: Ceiling not shown in illustration to ease understanding.

HA0079

A

LL

 

INSTALLATIONS

Remove protective plastic film covering the upper flue.

17. HOW TO INSTALL CHARCOAL FILTERS (NON-DUCTED INSTALLATION ONLY)

Using no. 6 x 1/2” provided screws, install one filter support on each side of the internal 
blower.

HA0080

Position each filter over its support, insert both pins (

A

) into the round slot (

B

) on filter side 

and rotate to lock in place.

HA0081

A

B

NOTE:  Replacement is recommended after 25 hours of cooking or six months of operation. Purchase charcoal filter kit no. 18524 (2 round 
 

 

filters per kit). Replace more often if your cooking habits generates more grease.

Summary of Contents for CONNAISSEUR CC32I SERIES

Page 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 AND 14 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Page 2: ...oper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and va...

Page 3: ...SUPPLIED WITH 09025 NON DUCT KIT 8 ROUND STANDARD DUCT 8 ROUND ADJUSTABLE ELBOW OPTIONAL MODEL 643 8 ROUND WALL CAP MODEL 401 STANDARD 3 X 10 DUCT CC32I SERIES RANGE HOOD SINGLE BLOWER SUPPLIED WITH...

Page 4: ...he unit it is recommended to wear safety glasses and gloves 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION Non duct kit model 09025 is required for a non ducted installation 2 2 DUCTED INSTALL...

Page 5: ...TH HOOD 30 WIDTH HOOD VERTICAL DISCHARGE OR NON DUCTED INSTALLATION HORIZONTAL DISCHARGE HD0391 1 2 4 CHOOSE THE OPENING VERTICAL DISCHARGE OR NON DUCTED INSTALLATION Using a Robertson or a Phillips n...

Page 6: ...ed to receive the adapter Before performing the installation make sure the adapter fits easily in the duct If this hood replaces another one please note that the location of the air exhaust can vary f...

Page 7: ...ounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be pl...

Page 8: ...of its screws Drill the 3 screw holes using a 3 16 drill bit Insert the included drywall anchors into the drilled holes 1 per hole Secure the upper flue bracket to the wall using 3 no 8 x 3 4 screws...

Page 9: ...s assemble the 8 round adapter to the lower plenum plate HD0382 A A Carefully align the upper plenum plate central notch with the line traced in step 9 see inset at right and place it flush to the cei...

Page 10: ...Y VERTICAL DISCHAGE Plug hood power cord into the outlet Slide a 8 metal round duct over the adapter damper on the hood Use metal foil duct tape to seal the joint HJ0037 NON DUCTED INSTALLATION Plug h...

Page 11: ...move protective plastic film covering the lower flue only then just peel off the plastic film covering both top corners of the upper decorative flue Position the lower flue rear notches down the ones...

Page 12: ...the plenum sides using 2 no 8 x 1 4 screws included per side NOTE Ceiling not shown in illustration to ease understanding HA0079 ALL INSTALLATIONS Remove protective plastic film covering the upper fl...

Page 13: ...metal filters in the dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions but this will not affect fi...

Page 14: ...B START STOP SPEED SELECTION SWITCH Press the switch corresponding to the desired blower speed from 1 for low speed to 4 for high speed The chosen switch will light To turn off the blower press once m...

Page 15: ...e the product will be repaired or replaced at Venmar s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar...

Page 16: ...OUND CHARCOAL FILTERS 2 PER KIT 1 17 09016 ROUND CHARCOAL FILTER SUPPORT 2 18 09017 8 ROUND METAL FLEXIBLE DUCT 1 19 08543 8 ROUND ADAPTER 1 20 18509 LOWER PLENUM PLATE 1 21 18508 UPPER PLENUM PLATE 1...