Venmar CONNAISSEUR CC32I SERIES Installation Instructions Manual Download Page 14

14

21. OPERATION

Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to 
clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

HC0023

B

D

20. CARE 

(CONT'D)

Hood cleaning

Avoid when choosing a detergent:

-  Any cleaners that contain 

bleach

 will attack stainless steel.

-  Any products containing: 

chloride, fluoride, iodide, bromide

 will deteriorate surfaces rapidly.

-  Any combustible products used for cleaning such as 

acetone, alcohol, ether, benzol

, etc., are highly explosive and should never be 

used close to a range.

Do:

•  Regularly wash with clean cloth or rag soaked with warm water 

and mild soap or liquid dish detergent.

•  Always clean in the direction of original polish lines.

•  Always rinse well with clear water (2 or 3 times) after cleaning. 

Wipe dry completely.

•  You may also use a specialized household stainless steel 

cleaner.

Don’t:

•  Use any steel or stainless steel wool or any other scrapers to 

remove stubborn dirt.

•  Use any harsh or abrasive cleansers.

•  Allow dirt to accumulate.

•  Let plaster dust or any other construction residues reach the 

hood. During construction/renovation, cover the hood to make 
sure no dust sticks to stainless steel surface.

C

A

A. D

ELAY

 S

WITCH

:

 

When a blower speed is selected, press this switch to activate the delay function. The corresponding blower speed switch will flash to 

 

indicate this function is activated. The blower will continue to operate for 5 minutes and will stop automatically.

 

To cancel the delay function, press the delay switch once again.

B. S

TART

/S

TOP

/S

PEED

 S

ELECTION

 S

WITCH

:

 

Press the switch corresponding to the desired blower speed (from 

1

 for low speed to 

4

 for high speed). The chosen switch will light. To 

 

turn off the blower, press once more on the corresponding blower speed switch; the switch light will shut off.

 

NOTE: When blower is off, pressing on blower speed 

1

 switch will cause the blower to start on high speed for a very short lapse of 

 

 

time, and then resume on speed 

1

.

C. M

ASTER

 OFF/F

ILTER

 M

AINTENANCE

/H

EAT

 S

ENTRY

™ (T

RIPLE

 F

UNCTION

 S

WITCH

):

 

i.  To turn off the blower and the light simultaneously, press this switch once.

 

ii.  After 25 hours of operation, this switch will light to indicate the filters and the blower wheel need to be cleaned in order to maintain 

 

 

efficient operation of the unit. The switch light will stay on until the function is reset by pressing this switch for 3 seconds.

 

iii.  The light indicator is used for the Heat Sentry function as well.

 

H

EAT

 S

ENTRY

When an excessively high temperature is detected, the detector takes control over the blower and set it on speed 

3

; its 

 

 

   

switch light comes on and the Heat Sentry switch flashes.

 

 

   

The blower will remain on until the heat is back to normal, it then returns to the speed previously selected.

  WARNING

!

The Heat Sentry can start the blower even if the hood is turned off. When this situation occurs, it is impossible to 
turn the blower off using the push buttons. If you must stop the blower, do it from the main electrical panel.

 

NOTE:  In a case of range top grease fire (temperature exceeding 90°C), the Heat Sentry will be deactivated to prevent fire propagation.

D. L

IGHT

 S

WITCH

:

 

This switch allows two different lighting levels according to your needs. Press once for full intensity, twice for nightlight.To shut off the

 

lights without turning the blower off, press once more.

Summary of Contents for CONNAISSEUR CC32I SERIES

Page 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 AND 14 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Page 2: ...oper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and va...

Page 3: ...SUPPLIED WITH 09025 NON DUCT KIT 8 ROUND STANDARD DUCT 8 ROUND ADJUSTABLE ELBOW OPTIONAL MODEL 643 8 ROUND WALL CAP MODEL 401 STANDARD 3 X 10 DUCT CC32I SERIES RANGE HOOD SINGLE BLOWER SUPPLIED WITH...

Page 4: ...he unit it is recommended to wear safety glasses and gloves 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION Non duct kit model 09025 is required for a non ducted installation 2 2 DUCTED INSTALL...

Page 5: ...TH HOOD 30 WIDTH HOOD VERTICAL DISCHARGE OR NON DUCTED INSTALLATION HORIZONTAL DISCHARGE HD0391 1 2 4 CHOOSE THE OPENING VERTICAL DISCHARGE OR NON DUCTED INSTALLATION Using a Robertson or a Phillips n...

Page 6: ...ed to receive the adapter Before performing the installation make sure the adapter fits easily in the duct If this hood replaces another one please note that the location of the air exhaust can vary f...

Page 7: ...ounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be pl...

Page 8: ...of its screws Drill the 3 screw holes using a 3 16 drill bit Insert the included drywall anchors into the drilled holes 1 per hole Secure the upper flue bracket to the wall using 3 no 8 x 3 4 screws...

Page 9: ...s assemble the 8 round adapter to the lower plenum plate HD0382 A A Carefully align the upper plenum plate central notch with the line traced in step 9 see inset at right and place it flush to the cei...

Page 10: ...Y VERTICAL DISCHAGE Plug hood power cord into the outlet Slide a 8 metal round duct over the adapter damper on the hood Use metal foil duct tape to seal the joint HJ0037 NON DUCTED INSTALLATION Plug h...

Page 11: ...move protective plastic film covering the lower flue only then just peel off the plastic film covering both top corners of the upper decorative flue Position the lower flue rear notches down the ones...

Page 12: ...the plenum sides using 2 no 8 x 1 4 screws included per side NOTE Ceiling not shown in illustration to ease understanding HA0079 ALL INSTALLATIONS Remove protective plastic film covering the upper fl...

Page 13: ...metal filters in the dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions but this will not affect fi...

Page 14: ...B START STOP SPEED SELECTION SWITCH Press the switch corresponding to the desired blower speed from 1 for low speed to 4 for high speed The chosen switch will light To turn off the blower press once m...

Page 15: ...e the product will be repaired or replaced at Venmar s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar...

Page 16: ...OUND CHARCOAL FILTERS 2 PER KIT 1 17 09016 ROUND CHARCOAL FILTER SUPPORT 2 18 09017 8 ROUND METAL FLEXIBLE DUCT 1 19 08543 8 ROUND ADAPTER 1 20 18509 LOWER PLENUM PLATE 1 21 18508 UPPER PLENUM PLATE 1...