Venmar CIC700I16WG Installation Instructions Manual Download Page 18

13. OPERATION (

CONT

D

)

- 18 -

E

RASE

 L

INK

 P

ROCESS

1.A

CTIVATE THE

L

INK MODE OF THE RANGE HOOD

Push and hold button 

E

for 3 seconds. After the 3-second hold, button 

E

backlight blinks 

3 times quickly (low to high intensity) and then all 4 speed levels backlights start to oscillate
between mid and low.

2.E

RASE ALL LINKED

L

INK

L

OGIC DEVICES

Push and hold button 

B

for 3 seconds to start the “Erase-link” process, all 4 speed levels

backlights flash in rotation until links are erased (not visible when small number of linked
devices).

3.E

XIT THE

L

INK MODE OF THE RANGE HOOD

Press and hold button 

E

for 3 seconds. After the 3-second hold, button 

E

backlight blinks 

3 times quickly (low to high intensity) and it exits the 

Link mode. Link mode remains activated

for 4 minutes if no other operation is done.

14.WARRANTY

VENMAR VENTILATION FIVE-YEAR WARRANTY

Venmar Ventilation Inc. warrants to the original consumer purchaser of the Venmar Connaisseur
CIC700 Series range hood that such product will be free from defects in materials or workmanship for
a period of five (5) years from date of original purchase. This warranty includes in-home service for the
first year and workshop service for the four (4) remaining years.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
VENMAR VENTILATION INC. WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE
ORIGINAL PURCHASE PRICE OF A VENMAR CONNAISSEUR CIC700 SERIES RANGE HOOD
NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During the period stated above, Venmar Ventilation Inc. will, at its option, repair or replace without
charge any product or part which is found to be defective under normal use and service. THIS 
WARRANTY DOES NOT EXTEND TO ANY LIGHT BULBS AND FILTERS.
This warranty does not cover a) normal maintenance and service b) any products or parts which have
been subject to misuse, negligence, accident, improper maintenance or repairs made by other than
Venmar Ventilation Inc., or c) a faulty installation or installation contrary to recommended installation
instructions.
Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation
Inc. Where applicable, in-home service will be made available only in areas where a contracted 
service provider offers service. If in-home service is not available, the product will be repaired or
replaced, at Venmar’s discretion, by the nearest authorized service provider. The unit removal and 
reinstallation works are under the customer responsibility, and Venmar cannot be charged for them.
The duration of any implied warranty is limited to the 5-year period as specified for the express 
warranty. Some provinces do not allow limitation on how long an implied warranty lasts, so the above
limitation may not apply to you.
VENMAR VENTILATION INC'S OBLIGATION TO REPAIR OR REPLACE AT VENMAR 
VENTILATION INC'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE 
REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION INC SHALL NOT BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. SOME PROVINCES DO NOT ALLOW THE 
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from
province to another. This warranty supersedes all prior warranties.
To contact Venmar Ventilation Inc. warranty service call 1-800-567-3855 in Canada. In order to qualify
for a warranty claim, the owner of a Venmar Connaisseur CIC700 Series range hood must have the
model and serial number along with a proof of the original purchase date. At the time of requesting
service, describe the nature of any defect in the product or part.

Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville, QC  J2C 7W9   (1-800-567-3855)

www.venmar.ca    www.ispira.ca

Summary of Contents for CIC700I16WG

Page 1: ...HOMEOWNER USE AND CARE INFORMATION ON PAGES 15 TO 18 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional informat...

Page 2: ...or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should no...

Page 3: ...to perform most efficiently Install proper sized ductwork elbows and roof cap Connect metal ductwork to cap and work back towards the hood location Use 2 metal foil duct tape to seal the joints Run 3...

Page 4: ...uded Hood Accessories Decorative flue assembly lower and upper flues 2 Shielded halogen bulbs 120 V 50 W MR16 with GU10 base 2 Baffle filters 4 Filter knobs with screws taped inside the hood 1 Ceiling...

Page 5: ...ece of cardboard to avoid damaging the table or the hood Remove tape on filters Lift filters by pushing them towards the back opposite control side and rotate then set filters aside 3 PREPARE HOOD HO0...

Page 6: ...ired according to height C HH0156A C B A CEILING COOKTOP BLOWER BOX BOTTOM RANGE HOOD BOTTOM 93 8 C B A 93 8 C REQUIRED COMPONENTS FROM TO BRACKETS UPPER FLUE LOWER FLUE OPTIONAL FLUE BEND TABS 14 18...

Page 7: ...upport the total weight of the hood and should not be larger than 9 x 9 10 10 93 8 93 8 103 8 103 8 HK0062A MAX 9 FRAMING INNER EDGE When building framework always follow all applicable construction c...

Page 8: ...the sides without a T will be facing the front of the hood Secure mounting bracket to the ceiling using 8 no 10 x 1 wood screws 2 for each corner Make sure screws are driven into the center of the fr...

Page 9: ...for a 10 ft ceiling discard the provided upper flue and use the optional extension flue part no 19325 sold separately 4 additional angle brackets and additional mounting hardware are included with th...

Page 10: ...nd blower box is level and square as shown at right then tighten all screws 6 ASSEMBLE ANGLE BRACKETS CONT D 10 HD0420 FRONT OF THE HOOD FRONT OF THE HOOD SIDE VIEWS OF THE BLOWER BOX CORRECT INCORREC...

Page 11: ...e ductwork rough in in the ceiling Connect this section of duct to the adapter damper then connect to ceiling duct and seal both joints with metal foil duct tape HD0434 HOUSE WIRING 5 Connect hood pow...

Page 12: ...d holes some parts not illustrated to ease understanding NOTE Install the glass panel with the control pictograms on the front of the hood 3 While holding glass panel pre tighten previously removed nu...

Page 13: ...rts not illustrated to ease understanding NOTE For more convenience a total of 16 holes 4 holes per section are available to secure the hood but only 1 screw per section is necessary HD0433 SCREW LOCA...

Page 14: ...tion 1 Using a Phillips no 2 screwdriver assemble two knobs to each filter The screws MUST BE on filter tabs side See illustration at right 10 REINSTALL BAFFLE FILTERS HO0195 FILTER TABS CAUTION Remov...

Page 15: ...nless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the hood During co...

Page 16: ...gh intensity and flash 3 times it will then fade out to its low intensity to indicate that the control interface is unlocked B E SPEED SELECTION BUTTONS Press the button corresponding to the desired b...

Page 17: ...or until beep is heard When the tab is released the remote control confirms initialization by turning ON the backlight of the Room Light ON and Off button Press the Room Light OFF button to stop the f...

Page 18: ...y products or parts which have been subject to misuse negligence accident improper maintenance or repairs made by other than Venmar Ventilation Inc or c a faulty installation or installation contrary...

Page 19: ...5 J8 BLU WHT ORG BLK YEL BLK WHT WHT HE0127A 120 VAC L INE N EUTRAL G ROUND F AN MOTOR BLU WHT ORG BLK GRY BRN WHT 25 F 4 3 2 1 3 2 1 3 2 1 COLOR CODE BLK BLU BRN GRY ORG BLACK BLUE BROWN GREY ORANGE...

Page 20: ...ASS PANEL COLOR 20 KEY NO PART NO DESCRIPTION QTY 1 SV19232 CEILING MOUNTING BRACKET 1 2 SV19240 UPPER DECORATIVE FLUE 1 3 SV19239 LOWER DECORATIVE FLUE 1 4 SV08543 8 ROUND ADAPTER DAMPER 1 5 SV09958X...

Reviews: