- 11 -
7. CONNECT WIRING (
CONT
’
D
)
3. Run house wiring through wire clamp and
into blower box electrical box. Tighten wire
clamp to secure house wiring cable to
blower box.
4. Measure the required length of 8" round
metal duct from the adapter/damper to the
ductwork rough-in in the ceiling. Connect
this section of duct to the adapter/damper,
then connect to ceiling duct and seal both
joints with metal foil duct tape.
HD04
3
4
H
OUSE
WIRING
5. Connect hood power cable to house wiring
using provided wire connectors: BLACK to
BLACK, WHITE to WHITE and GREEN or
BARE wire to GREEN ground screw.
DO
NOT FORGET TO CONNECT THE
GROUND.
6. Reinstall electrical box cover using both
screws previously removed.
HE0126