Venmar CIC700I16WG Installation Instructions Manual Download Page 12

1. Slide the upper flue up to the ceiling and secure it to

the ceiling mounting bracket using 2 no. 8 x 1/2"
quadrex screws.

NOTE: Ensure upper and lower flue seams are 

aligned     .

Carefully slide the lower flue over the upper flue up
to the ceiling and have the second person hold it to
the ceiling     while performing step 2.

For each glass panel:

1. Remove glass panel from its packaging.

Remove glass panel nuts (factory installed) from both studs and set aside.

2. Insert glass panel studs in appropriate hood

holes (some parts not illustrated to ease 
understanding).

NOTE: Install the glass panel with the control 

pictograms on the front of the hood.

3. While holding glass panel, pre-tighten previously

removed nuts by hand. Ensure glass panel is
centered.

Then, using a 3/8" socket, tighten nuts completely.

8. INSTALL GLASS PANELS (

WG MODEL ONLY

)

The WG hood model glass panels are sold separately and have to be installed before completing
the hood installation.

HD0438

G

LASS PANEL

STUD

N

UT

1

2

HD04

3

5

- 12 -

CAUTION

DO NOT REMOVE the protective plastic film covering the decorative flue (upper
and lower) yet.

9. INSTALL HOOD

BE CAREFUL when installing the decorative flue and hood, they may have
sharp edges.

WARNING

!

1

2

Summary of Contents for CIC700I16WG

Page 1: ...HOMEOWNER USE AND CARE INFORMATION ON PAGES 15 TO 18 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional informat...

Page 2: ...or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should no...

Page 3: ...to perform most efficiently Install proper sized ductwork elbows and roof cap Connect metal ductwork to cap and work back towards the hood location Use 2 metal foil duct tape to seal the joints Run 3...

Page 4: ...uded Hood Accessories Decorative flue assembly lower and upper flues 2 Shielded halogen bulbs 120 V 50 W MR16 with GU10 base 2 Baffle filters 4 Filter knobs with screws taped inside the hood 1 Ceiling...

Page 5: ...ece of cardboard to avoid damaging the table or the hood Remove tape on filters Lift filters by pushing them towards the back opposite control side and rotate then set filters aside 3 PREPARE HOOD HO0...

Page 6: ...ired according to height C HH0156A C B A CEILING COOKTOP BLOWER BOX BOTTOM RANGE HOOD BOTTOM 93 8 C B A 93 8 C REQUIRED COMPONENTS FROM TO BRACKETS UPPER FLUE LOWER FLUE OPTIONAL FLUE BEND TABS 14 18...

Page 7: ...upport the total weight of the hood and should not be larger than 9 x 9 10 10 93 8 93 8 103 8 103 8 HK0062A MAX 9 FRAMING INNER EDGE When building framework always follow all applicable construction c...

Page 8: ...the sides without a T will be facing the front of the hood Secure mounting bracket to the ceiling using 8 no 10 x 1 wood screws 2 for each corner Make sure screws are driven into the center of the fr...

Page 9: ...for a 10 ft ceiling discard the provided upper flue and use the optional extension flue part no 19325 sold separately 4 additional angle brackets and additional mounting hardware are included with th...

Page 10: ...nd blower box is level and square as shown at right then tighten all screws 6 ASSEMBLE ANGLE BRACKETS CONT D 10 HD0420 FRONT OF THE HOOD FRONT OF THE HOOD SIDE VIEWS OF THE BLOWER BOX CORRECT INCORREC...

Page 11: ...e ductwork rough in in the ceiling Connect this section of duct to the adapter damper then connect to ceiling duct and seal both joints with metal foil duct tape HD0434 HOUSE WIRING 5 Connect hood pow...

Page 12: ...d holes some parts not illustrated to ease understanding NOTE Install the glass panel with the control pictograms on the front of the hood 3 While holding glass panel pre tighten previously removed nu...

Page 13: ...rts not illustrated to ease understanding NOTE For more convenience a total of 16 holes 4 holes per section are available to secure the hood but only 1 screw per section is necessary HD0433 SCREW LOCA...

Page 14: ...tion 1 Using a Phillips no 2 screwdriver assemble two knobs to each filter The screws MUST BE on filter tabs side See illustration at right 10 REINSTALL BAFFLE FILTERS HO0195 FILTER TABS CAUTION Remov...

Page 15: ...nless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the hood During co...

Page 16: ...gh intensity and flash 3 times it will then fade out to its low intensity to indicate that the control interface is unlocked B E SPEED SELECTION BUTTONS Press the button corresponding to the desired b...

Page 17: ...or until beep is heard When the tab is released the remote control confirms initialization by turning ON the backlight of the Room Light ON and Off button Press the Room Light OFF button to stop the f...

Page 18: ...y products or parts which have been subject to misuse negligence accident improper maintenance or repairs made by other than Venmar Ventilation Inc or c a faulty installation or installation contrary...

Page 19: ...5 J8 BLU WHT ORG BLK YEL BLK WHT WHT HE0127A 120 VAC L INE N EUTRAL G ROUND F AN MOTOR BLU WHT ORG BLK GRY BRN WHT 25 F 4 3 2 1 3 2 1 3 2 1 COLOR CODE BLK BLU BRN GRY ORG BLACK BLUE BROWN GREY ORANGE...

Page 20: ...ASS PANEL COLOR 20 KEY NO PART NO DESCRIPTION QTY 1 SV19232 CEILING MOUNTING BRACKET 1 2 SV19240 UPPER DECORATIVE FLUE 1 3 SV19239 LOWER DECORATIVE FLUE 1 4 SV08543 8 ROUND ADAPTER DAMPER 1 5 SV09958X...

Reviews: