background image

 
 

MA-SE-HE00-01-11 Manual HEMA eng rev11 

 

Page 

4

 of 

8

 

 

 

2.

 

THREE-WIRE CONNECTION 

Connect 13.8 Vdc supplying coming from control panel to the dedicated terminals:

 

-RIC negative; +RIC positive. (+C trigger must be jumped to +RIC ); RES negative trigger for flash reset. 

      

Note: by default, DIPSWITCH N°2 is set in OFF N°6 OFF, POSITIVE-MISSING TRIGGER 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

 

HEMA LSP MODEL WIRING 

Connect 13.8 Volt supplying coming from control panel to the dedicated terminals:

 

-RIC negative; +RIC positive; +C positive-missing trigger; RES negative trigger for flash reset. 
Note: by default, DIPSWITCH N°2 is set in OFF position, POSITIVE-MISSING TRIGGER 

Only in HEMA LSP model, terminal M9 must be jumpered to terminal M10 TAMPER A.P. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

 

OPTICAL INDICATION OF SYSTEM STATUS (MOMENTARY OR PERMANENT ON-OFF) 

 

If a positive is given to terminal STI (System status) all LEDs of the flashing light make 3 flashes (ON);  

 

If the positive is removed, all LEDs light on steady for 5 seconds (OFF) and the complete sounder test is launched (remote test). 

 
By default, DIPSWITCH N°4 is set in OFF position (MOMENTARY ON-OFF) 
DIPSWITCH N°4 in ON position (MOMENTARY ON-OFF) and 1 LED keeping on flashing as long as positive tension = 0V is given to terminal STI. 

 

5.

 

SOUNDER TIMING  

By default, timing is 3 minutes (DIPSWITCH N°1 in OFF position) and it can be modified into 8 minutes. 

 

+13.8 Vdc and OUTDOOR SOUNDER 

TRIGGER  

TAMPER LINE 

GND 0 Vdc 

ALARM CONTROL PANEL 

SOUNDER 

+13.8 Vdc 

GND 0 Vdc 

OUDOOR SOUNDER TRIGGER 

TAMPER LINE 

ALARM CONTROL PANEL 

SOUNDER 

FLASH RESET 

TRIGGER 

FLASH RESET 

TRIGGER 

Summary of Contents for HEMA L

Page 1: ...ty inversion and tropicalized through a special resin tropicalization process against bad weather conditions and moisture External cover and sounder base are in ABS while the internal cover is made of...

Page 2: ...from 20 to 100 of RH Size 330x210x110 H x L x W Weight 1 957 gr Standards compliance T031 2014 EN50131 4 2009 Security L and LS models Grade 3 LSP model Grade 4 MOUNTING 1 Use the 6mm plugs to fix the...

Page 3: ...positive missing trigger RES negative trigger for flash reset Note by default DIPSWITCH N 2 is set in OFF position POSITIVE MISSING TRIGGER LEFT FLASH RIGHT FLASH ANTI DRILLING ANTI DRILLING TAMPER T...

Page 4: ...ered to terminal M10 TAMPER A P 4 OPTICAL INDICATION OF SYSTEM STATUS MOMENTARY OR PERMANENT ON OFF If a positive is given to terminal STI System status all LEDs of the flashing light make 3 flashes O...

Page 5: ...lts too At the first sounder supplying 13 8 Vdc or battery anomalies automatically reset once the cause disappears this makes the installation easier After the first activation of the sounder anomalie...

Page 6: ...Vdc C 3 Sounder control chart 5 STI 4 ON OFF indication of alarm system status 5 Input for sound block OUT ANM 6 Fault output Open collector 0 Vdc no anomaly RES 7 Flash reset TAMPER 8 Self protection...

Page 7: ...on for 4 seconds then switch off ON 12 Vdc All LEDs flash 3 times and 1 LED keeps on flashing Not connected or 0 Vdc All LEDs remain steady on for 4 seconds then switch off Chart 8 flash reset mode D...

Page 8: ...01 11 Manual HEMA eng rev11 Page 8 of 8 Product manufactured in Italy Venitem s r l via del Lavoro 10 30030 Salzano VE ITALY Tel 39 0415740374 Fax 39 0415740388 E mail info venitem com website www ve...

Reviews: