![VendNet 3120-GF12 II Service Manual Download Page 6](http://html1.mh-extra.com/html/vendnet/3120-gf12-ii/3120-gf12-ii_service-manual_4021700006.webp)
4
CHANGING TRAY
CONFIGURATION AND
RETIMING
Removing and Replacing Trays
To remove a tray from the vendor:
1.
Pull out the tray to be removed until it stops.
2.
Disconnect the tray harness and undo any
clamps. See Figure 3.
3.
GF19 II and GF35 II:
Disconnect the main
harness from the tray plug.
GF12 II:
Remove harness from slot in right-
side wall and disconnect harness plug.
4.
Lift up on the front of the tray and pull
slightly forward (approximately 1/2 inch/1.5
cm) to clear the tray stop.
GF12 II
GF19 II & GF35 II
Figure 3. Tray Harness Connections
5.
Lift up on the rear of the tray and remove it
from the vendor.
To replace a tray in the vendor:
6.
GF19 II and GF35 II:
Place the back of the
tray on the rails by placing its rear rollers on
the left and right rails and lifting up on the
front of the tray as you push it back.
GF12 II:
Place the back of the tray on the
rails and lift up to clear the tray stops.
Slide tray into machine until it stops, lift up
slightly on front of tray and push in to lock
into detent position.
7.
GF19 II and GF35 II:
Connect the main
harness to the tray plug.
Re-clamp the main harness if necessary.
GF12 II:
Connect harness plug. Install
harness tubing into slot in right-side wall.
8.
Test vend the tray to assure that the tray plug
is properly seated and all motors are
working.
Changing Timing
The shape, size and thickness of product affects
how well it falls off the tray. If vending problems
occur with auger ends at the standard 6 o’clock
position, adjust the drop off either with product
pushers or by retiming the auger.
Product pushers
Order product pushers. P/N 4025748
Snaps on to end of auger. See Figure 4.
Test vend and adjust if necessary.
Figure 4. Product Pushers