2
SPECIFICATIONS
Cabinet
Inches
Metric
Height
68
173 cm
Depth
GF12 II
33 1/2
87 cm
EC14
35 1/2
90.2cm
GF19 II
30 1/8
76.5 cm
GF35 II
30 1/8
76.5 cm
Width
GF12 II
21
53.3cm
EC14
21
53.3cm
GF19 II
28
71.1 cm
GF35 II
38
96.5 cm
Lbs
kg
Weight
GF12 II
341
155
EC14
350
159
GF19 II
391
177
GF35 II
476
216
Glass
Use 1/8-inch (3.175 mm) tempered glass only
Inches
Metric
Height
All
42.244
107.3
Width
GF12 II
9.062
23
EC14
9.062
23
GF19 II
14.187
36
GF35 II
24.687
62.7
Electrical
Power
115 VAC
220 VAC
Cycle
60 Hz
50 Hz
Current
1 Amp
1 Amp
Capacity
80-Select Controller Options:
Up to 80 Snack Selections or
60 Snack Selections &
12 Satellite Canned Drink Selections
Pricing
MDB Coin Mechanism
UNPACKING & INSTALLATION
To minimize installation time and to avoid
service problems due to improper installation,
follow the instructions outlined in this manual.
This machine has been thoroughly inspected
before leaving the factory. The delivering carrier
has accepted this vendor as its responsibility.
Any damage or irregularities should be noted at
the time of delivery and reported to the carrier.
Request a written inspection report from the
claims inspector to file any claim for damage.
File the claim with the carrier (not the
manufacturer) within 15 days after receipt of the
machine.
Carefully remove the outside packing material in
a manner not to damage the finish or exterior of
the machine. Inspect the machine for concealed
shipping damage. Report any damage hidden by
the shipping material directly to the delivering
carrier on a hidden damage report.
Record the model number and serial number of
the vendor for your records. These numbers are
on the Serial Plate on the back or inside of the
cabinet. Refer to these numbers on all
correspondence and inquiries pertaining to this
vendor.
Remove the "Knock-A-Way" skid boards. Place
a 2 x 4 under the vendor, insert a screwdriver or
prying tool into the groove of the Knock-A-Way
and split it in two. Turn the leveling screws in as
far as possible. See Figure 1.
Position the vendor no further than nine feet
(2.74 meters) from the power outlet or receptacle
and check that the door will open fully without
interference.
Level the vendor, making sure all levelers are
touching the floor. The vendor must be level for
proper operation and acceptance of coins through
the coin mechanism. When the vendor is level,
the door can be opened to any position and not
move by itself. Try the door half closed, straight
out and in a wide-open position.